Maintenance and repair
C
138
AXIS-GENERAL
AXIS
20.1
AXIS
30.1 (W), AXIS 40.1 (W)
C.2
Weight spreader lubrication
Figure 17:
Weight spreader lubrication point
C.3
Check the screw connections in the weighing cell
The solid fertiliser broadcaster comes with 2 weighing cells, which are mounted
with 2 bolted connections per cell. The tie rod has one bolted connection.
Check the bolted connections for the weighing cells and the tie rod for tightness
on both sides of the solid fertiliser broadcaster:
before every spreading season
also during the spreading season, if necessary.
Check:
1.
Tighten the bolted connec-
tion with a torque wrench
(torque =
300 Nm
).
Figure 18:
Fasten the weighing cell (on the
left of the travelling direction)