Maintenance and repair
141
C
AXIS
20.1
AXIS
20.1
AXIS
30.1 (W), AXIS 40.1 (W)
Adjustment:
The metering slide is in the position of step 2 (lightly pressed against the pin).
3.
Release the retaining screws on the scale of the lower scale plate.
Figure 21:
Metering slide adjustment scale
4.
Adjust the scale in a way that the
scale value 85
lies exactly under the display
pointer. Screw the scale tight.
5.
Repeat steps 1 - 4 for the right metering slide.
6.
Replace the returning springs and hydraulic cylinders.
NOTICE
Both metering slides must open
evenly
. Always test both metering slides.
NOTICE
After scale correction with electric slide controls, a correction of the slide testing
points in the electric controls is also necessary.
Please refer to the operating instructions for the electronic control system.
Summary of Contents for AXIS 20.1
Page 4: ......
Page 12: ...Contents VIII...
Page 14: ...Intended use 1 2 AXIS GENERAL...
Page 46: ...Transport without tractor 6 34 AXIS GENERAL...
Page 48: ...Instructions regarding the spreading process 7 36 AXIS GENERAL...
Page 156: ...Maintenance and repair C 144 AXIS GENERAL AXIS 20 1 AXIS 30 1 W AXIS 40 1 W...
Page 194: ...Appendix D 182 AXIS GENERAL AXIS 20 1 AXIS 30 1 W AXIS 40 1 W AXIS 50 1 W...
Page 214: ......
Page 215: ......