Spreading Operation
B
100
AXIS-GENERAL
AXIS
20.1
Metering slide does not open
Metering slides do not move easily. Regularly check
nuts and screws for tight fit and tighten them, if
necessary.
Check tension spring.
The reducing plate on the hose connection of the fe-
male coupler is dirty.
Metering slide opens too slowly
Clean orifice plate.
Replace 0.7 mm orifice plate with a 1.0 mm plate. The
plate is at the hose connection of the female coupler.
Agitator does not operate
Check agitator drive. See
.
Blockage of metering outlets by:
fertiliser clumps, damp fertiliser,
miscellaneous impurities (leaves,
straw, sack residues)
Clear blockages. Proceed as follows:
1.
Park tractor, remove ignition key
2.
Open metering slides
3.
Place catch basin underneath
4.
Remove spreading discs
5.
Clean the outlet
from below
with a wooden pole or
clean the adjustment lever and push through the meter-
ing opening,
6.
Remove foreign objects in hopper
7.
Install spreading discs, close metering slides
The spreading discs do not turn
or they stop suddenly after being
turned on
If you are using a universal drive shaft with shear pin attach-
ment:
Check the shear bolt coupling and replace if necessary
(see the universal drive shaft manufacturer's manual).
Fault
Possible cause/action
Summary of Contents for AXIS 20.1
Page 4: ......
Page 12: ...Contents VIII...
Page 14: ...Intended use 1 2 AXIS GENERAL...
Page 46: ...Transport without tractor 6 34 AXIS GENERAL...
Page 48: ...Instructions regarding the spreading process 7 36 AXIS GENERAL...
Page 156: ...Maintenance and repair C 144 AXIS GENERAL AXIS 20 1 AXIS 30 1 W AXIS 40 1 W...
Page 194: ...Appendix D 182 AXIS GENERAL AXIS 20 1 AXIS 30 1 W AXIS 40 1 W AXIS 50 1 W...
Page 214: ......
Page 215: ......