Maintenance and repair
C
106
AXIS-GENERAL
AXIS
20.1
To adjust:
The metering slide is in the position of step 2 (lightly pressed against the pin).
3.
Slacken the retaining screws on the bottom scale of the scale plate.
Figure 27:
Metering slide adjustment scale
4.
Adjust the scale in a way that the
scale value 85
lies exactly under the display
pointer. Screw the scale tight.
5.
Repeat steps 1 - 4 for the right metering slide.
6.
Replace the returning springs and hydraulic cylinders.
NOTICE
Both metering slides must open
by the same amount
. Always test both
metering slides.
NOTICE
After scale correction with electronic slide actuation, a correction of the slide
testing points in the electronic control system is necessary.
Please observe the operating instructions for the electric controls.