background image

 

        FFQG112S                                                                                              December. 2016 Copyright IDTECK Co., Ltd.

 

Quick Installation Guide 

 

 
 
 

 

 
 
 
 
 
 

 

 

 

 

 

 
 

 
 
 

NEO RF245 

 

LONG RANGE READER

 

Summary of Contents for NEO RF245

Page 1: ...FFQG112S December 2016 Copyright IDTECK Co Ltd Quick Installation Guide NEO RF245 LONG RANGE READER ...

Page 2: ...ight IDTECK Co Ltd Quick Installation Guide Table Of Contents 1 IDENTIFYING SUPPLIED PARTS 3 2 INSTALLATION OF THE PRODUCT 4 3 CABLE COLOR 7 4 WIRE CONNECTION TO CONTROLLER 8 5 OPERATION 9 6 PRODUCT MANUAL DOWNLOAD INFORMATION 13 ...

Page 3: ...Quick Installation Guide 1 Identifying Supplied Parts Unpack and check the contents If any of these parts are missing contact your distributor NEO RF245 Quick Installation Guide Mounting Bolts Mounting Bracket ON OFF Switch for Reading range setting ...

Page 4: ...FFQG112S December 2016 Copyright IDTECK Co Ltd Quick Installation Guide 2 Installation of the Product ...

Page 5: ... bargate loop coil and speed bump are for extra purchase IDTECK doesn t offer these contents Reading Angle of NEO RF245 The reading angle of RF245 is approximately 90 degree at the front side of the reader However the reader has about 10 of the maximum reading distance at the rear side of the reader ...

Page 6: ...each of them when installing multiple RF245 ex F 1 3m F 2 5m at least 2 In case of not being able to keep enough distance between two or more readers due to the spatial constraints a user can set desire reading range by adjusting the angle If it is difficult to have enough space between the NEO RF245 due to the spatial constraints 3 Using a reader hood will diminish the reading range therefore set...

Page 7: ...mum current drain rate is 1 Amps 2 HOLD input is used to force NEO RF245 to read a tag when loop sensor detects any approaching vehicle When a vehicle is detected NC contact should be used and the input should also be disconnected from GND completely In OTR mode the reader will only output tag ID 1 time CAUTION Nothing should be connected to this input unless loop sensor is in use 3 OTR cable yell...

Page 8: ...to Controller NEO RF245 Wire Connection Notice Connect both yellow OTR one time reading and white WIEGAND 1 cable to the ON OFF switch the switch must be ON when setting up reading range Turn ON the switch when setting up reading range Make sure to turn it OFF after a desired range is setup ...

Page 9: ...wire The BARGATE output is a transistor open collector output with the maximum current drain of 1 A 5 4 One time reading OTR control Input Connect OTR yellow cable to GND to activate One Time Reading mode During this state the reader will only generate output signal when a tag is detected for the first time If a user needs to scan the same tag again the particular tag must be completely out of the...

Page 10: ...nment that the users can freely set the reading range at the desired distance 5 6 Power off NEO RF245 5 7 Connect yellow OTR one time reading and white Wiegand_D1 cables together You can use a enclosed switch to connect two cables together as shown below The switch must be turned on before setting up reading range Make sure to turn off when finished ...

Page 11: ... location The tag should be scanned 10 straight times For the first 5 times of the scanning a single sound Bee will be generated From the 6th to 9th times of scanning double sound Bee Beep will be generated At the last 10th time of scanning triple sound Bee Bee Beep will be generated Now the distance of that 10th time of scanning will be programmed as a new reading distance When finished the readi...

Page 12: ...ading range is 2 meters and you want to maximize the reading range How 1 Follow the steps above 5 6 and 5 7 2 Wait until green LED turns off DO NOT scan any tag until it fully goes off 3 Follow the steps 5 9 to 5 10 Recognition distance shall be set with the maximum reading range Note 1 Reading range can have a margin of error that depends on installation circumstances 2 The default reading range ...

Page 13: ... select the product that you wish to download a manual for 4 At the bottom part of the product s page you selected click DOWNLOAD button and download the manual For un registered users of our homepage 1 Visit IDTECK s homepage www idteck com 2 Please click Member Join menu at the top of our homepage and register your details following the registration process 3 You can use your ID and P W after we...

Page 14: ...uick Installation Guide The specifications contained in this manual are subject to change without notice at any time 5F Ace Techno Tower B D 468 Gangseo ro Gangseo Gu Seoul 07573 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com ...