76
442704/A
Tip
If you do not have a computer keyboard connected to your ST90 system, select the
Keyboard
button to open an on-screen keyboard.
5
Select
OK
to save the chosen name.
6
Observe that the name you have chosen appears on the
Saved Settings
list.
7
Select
OK
to close the dialog box.
Related topics
Getting started, page 34
Basic operating procedures, page 71
User Settings dialog box, page 417
Defining the ping (transmission) modes
You can easily control how often the ST90 system shall transmit acoustic energy (a ping)
into the water. You can disable the transmission altogether, set it to operate as fast as
possible, or select a time interval.
Context
Once pinging is
On
, use
Transmission Mode
to choose
how often
the ST90 system shall transmit (ping). Use it
to control the
behaviour
of the transmissions (pinging).
•
Single Ping
: The ST90 system transmits (pings) only
when you click the ping symbol on the
Transmission
Mode
button.
•
Interval
: The ST90 system transmits (pings) with
a fixed time interval.
Ping Interval
permits you to choose the time (in milliseconds)
between each transmission (ping).
•
Maximum
: The ST90 system transmits (pings) as frequent as possible.
Procedure
1
Open the
Operation
menu.
2
Set
Operation
to
Normal
.
Simrad ST90 Reference Manual
Summary of Contents for Simrad ST90
Page 1: ...kongsberg com simrad Simrad ST90 REFERENCE MANUAL ...
Page 2: ......
Page 337: ...442704 A 335 Related topics Sonar views page 326 User interface ...
Page 413: ...442704 A 411 Related topics Menu system page 375 Display menu page 384 Menu system ...
Page 631: ...442704 A 629 Related topics Concept descriptions page 626 Concept descriptions ...
Page 687: ......
Page 688: ... 2021 Kongsberg Maritime ISBN 978 82 8066 211 8 ...
Page 689: ......
Page 690: ...Reference Manual Simrad ST90 ...