264
442704/A
b
Open the
Operation
menu.
1
Set
Operation
to
Normal
.
2
Set
Tx Power
to
Off
.
c
Open the
Active
menu.
1
Set
TVG
(Time Variable Gain) to
0 log R
.
2
Set
Ping-Ping Filter
to
Off
.
3
Set
Pulse Type
to
CW Short
.
4
Set
Frequency
to the start frequency:
5
Set
Horizontal TX Sector
to
Omni
.
6
Set
Vertical TX Sector
to
Normal
.
7
Set
AGC
(Automatic Gain Control) to
Off
.
8
Set
RCG
(Reverberation Controlled Gain) to
0
(zero).
9
Set
Noise Filter
to
Off
.
d
Open the
Setup
menu.
e
Select
Diagnostics
to open the dialog box.
f
Select
Noise
to open the page.
g
Select
Start Noise Measurements
.
5
Repeat for each vessel speed and operating frequency.
a
Ask the bridge to set the speed.
b
If possible, verify the vessel speed on the top bar.
c
Read the noise value from the noise circle.
d
Record the values in the result table.
e
Repeat for every 2 kHz up to and including the highest test frequency: 90 kHz
1
Increase the operating frequency with 2 KHz.
2
Read the noise value from the noise circle.
3
Record the values in the result table.
f
Ask the bridge to set the next speed.
6
When all the measurements have been made, type the data (speed and noise) into a
spreadsheet to create the curve.
Simrad ST90 Reference Manual
Summary of Contents for Simrad ST90
Page 1: ...kongsberg com simrad Simrad ST90 REFERENCE MANUAL ...
Page 2: ......
Page 337: ...442704 A 335 Related topics Sonar views page 326 User interface ...
Page 413: ...442704 A 411 Related topics Menu system page 375 Display menu page 384 Menu system ...
Page 631: ...442704 A 629 Related topics Concept descriptions page 626 Concept descriptions ...
Page 687: ......
Page 688: ... 2021 Kongsberg Maritime ISBN 978 82 8066 211 8 ...
Page 689: ......
Page 690: ...Reference Manual Simrad ST90 ...