290
442704/A
Note
Do not
use high-pressure water, sandblasting, metal tools or strong solvents to clean
the transducer.
Do not
damage the outer protective skin of the transducer.
6
Allow the transducer surface to dry.
7
Do a thorough visual inspection of the transducer.
Inspect it closely for any signs of dents, cracks, fractures or holes. If you find
suspicious damage, take high resolution photos that show the damage, and contact
Kongsberg Maritime support for advice.
8
Hoisting the transducer
a
Turn the crank until the transducer is fully retracted.
b
Loosen the brake release screw to engage the motor brake.
c
Check with the hand crank to ensure that the motor brake is engaged.
d
Remove the hand crank from the stub shaft, and mount it in its storage position in
the Motor Control Unit.
e
Activate the
Motor Protecting Switch
(S301) by pressing the operating handle to
ON
.
f
Make sure that the
Hoist/Lower Switch
is set to
REMOTE
.
Note
For normal operation from the Operating Panel, the switch must be set to
REMOTE.
g
Close the door on the Motor Control Unit.
Related topics
Maintenance procedures, page 186
Preventive maintenance, page 272
Preventive maintenance schedule, page 273
Approved anti-fouling paints, page 276
Preventive maintenance procedures, page 278
Simrad ST90 Reference Manual
Summary of Contents for Simrad ST90
Page 1: ...kongsberg com simrad Simrad ST90 REFERENCE MANUAL ...
Page 2: ......
Page 337: ...442704 A 335 Related topics Sonar views page 326 User interface ...
Page 413: ...442704 A 411 Related topics Menu system page 375 Display menu page 384 Menu system ...
Page 631: ...442704 A 629 Related topics Concept descriptions page 626 Concept descriptions ...
Page 687: ......
Page 688: ... 2021 Kongsberg Maritime ISBN 978 82 8066 211 8 ...
Page 689: ......
Page 690: ...Reference Manual Simrad ST90 ...