240
442704/A
d
Observe the "Physical Address" (MAC address) for the relevant Ethernet adapter.
e
Write down the information.
f
Close the
Command Prompt
window.
Select the adapter that the Operating Panel is connected to. On the ST90 system, the
Ethernet adapter is named Simrad Connect.
Prepare the Operating Panel for use.
2
Make the following preparations.
a
Connect the power cable from the Operating Panel to the power outlet on the
uninterruptible power supply (UPS).
b
Connect the Ethernet cable from the Processor Unit to the Operating Panel.
Make sure that you use the correct Ethernet socket on the rear side of the Processor
Unit: ETH1
c
Connect the keyboard and the mouse to USB sockets on the front panel of the
Processor Unit.
d
On the Processor Unit, close any programs that are running, and return to the
desktop.
e
On the Operating Panel, press
Power
, and keep it depressed for a few seconds.
The blue indicator light in the button flashes while the Operating Panel establishes
contact with the Processor Unit. When you start the panel for the first time the
interface must be configured to establish this connection. When the connection
has been made, the blue indicator light is lit permanently.
f
On the Processor Unit desktop, open folder
SIMRAD-Shortcut
.
g
Double-click file
IPandMACaddress.txt
to open it in a text editor.
h
Double-click the URL shortcut to open the Operating Panel configuration page in
the default web browser.
i
Observe that the Operating Panel configuration page opens on
page 157.237.60.20:5000.
3
Define the configuration parameters.
a
Select
SOP Configuration
on the top menu to open the page.
b
Observe the default values.
If you wish to keep these default values, do nothing. The default values are well
suited if you have one single panel communicating with one single Processor Unit.
For other configurations, see the relevant procedures.
4
Add a single Processor Unit to the Operating Panel configuration.
a
Select
Sonar PCs Configuration
on the top menu to open the page.
Simrad ST90 Reference Manual
Summary of Contents for Simrad ST90
Page 1: ...kongsberg com simrad Simrad ST90 REFERENCE MANUAL ...
Page 2: ......
Page 337: ...442704 A 335 Related topics Sonar views page 326 User interface ...
Page 413: ...442704 A 411 Related topics Menu system page 375 Display menu page 384 Menu system ...
Page 631: ...442704 A 629 Related topics Concept descriptions page 626 Concept descriptions ...
Page 687: ......
Page 688: ... 2021 Kongsberg Maritime ISBN 978 82 8066 211 8 ...
Page 689: ......
Page 690: ...Reference Manual Simrad ST90 ...