15
STATus Subsystem
434
Keysight 8990B Programming Guide
STATus Subsystem
The
STATus
command subsystem enables you to examine the status of the 8990B
by monitoring the following status registers:
– Device status register
– Operation status register
– Questionable status register
The contents of these and other registers in the 8990B are determined by one or
more status registers.
The following table summarizes the effects of various commands and events on
the status registers:
Table 15-1
Commands and events affecting the status registers
NOTE
Refer to “
Status Block Diagram
” at the end of this chapter to view the
relationship between various registers in the 8990B SCPI status system.
Status register
*RST
*CLS
Power on
STATus:
PRESet
SCPI Transition Filters (NTR and PTR registers)
none
none
preset
preset
SCPI Enable Registers
none
none
preset
preset
SCPI Event Registers
none
clear
clear
none
SCPI Error/Event Queue Enable
none
none
preset
preset
SCPI Error/Event Queue
none
clear
clear
none
IEEE-488.2 Registers ESE SRE
none
none
clear
none
IEEE-488.2 Registers ESR STB
none
clear
clear
none