ACQuire Subsystem
4
Keysight 8990B Programming Guide
89
ACQuire:CCDF:COUNt:CURRent?
This query returns the CCDF acquisition length of the running CCDF free run
sweep.
Syntax
Example
Remarks
– This query is only applicable for channels 1 and 4. If you send this query for a
channel other than 1 or 4, error 700,“Applicable to channel 1 and 4 only” will
occur.
– This query is only applicable in the CCDF acquisition mode. If the acquisition
mode is not set to CCDF, error –221,“Settings conflict;Requires CCDF mode to
be enabled” will occur. Refer to
“ACQuire:MODE <character_data>”
page 132 to set the acquisition mode.
– This query is only applicable when the CCDF sweep is set to the free run mode.
If the CCDF sweep is not set to free run, error –221,“Settings conflict;Requires
CCDF sweep to be in free run mode” will occur.
:COUN
ACQ
:CCDF
?
:CURR
ACQ:CCDF:COUN:CURR?
Queries the acquisition length of the running
CCDF free run sweep.
Summary of Contents for 8990B
Page 1: ...Keysight 8990B Peak Power Analyzer Programming Guide ...
Page 16: ...16 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 18: ...18 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 20: ...20 Keysight 8990B Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...