FUNCtion Subsystem
12
Keysight 8990B Programming Guide
349
NOTE
– From the Waveform Math dialog, you can toggle the
X
button to select
between multiplication symbol (x) or division symbol (/) as the symbol type..
The multiplication symbol (x) is the default setting. If the multiplication
symbol (x) is used, the constant value sent through SCPI will be updated in
the text box accordingly. If the division symbol (/) is used, the constant value
sent through SCPI will be displayed as 1/(constant value) in the text box.
– If the amplifier gain is more than 30 dB, the nominator can be set to a single
RF input channel.
– The power-added efficiency result is an absolute and non-negative value.
– The denominator PDC must be a real and non-zero value.
– The dBm and power conversion formula is 10
×
log (power/1 mW)
– If the trace lengths among the channels are not equal, the waveform math
operation will find the shortest trace among the sources and shrink the other
traces to an equal length.
– If the number of trace points is not equal, the waveform math operation will
add trace points by using the PCHIP method.
– If the source(s) input is in the log scale, it will be converted to the linear scale
to perform the power-added efficiency measurement.