ACQuire:DROop:SOURce CHAN{1|4|ALLRF|NONE}
This command sets the source of either channel 1, channel 4, or all RF channels
for the droop measurement.
Syntax
Example
Remark
If a channel other than channel 1 or 4 is specified, error 700,“Applicable to
channel 1 and 4 only” will occur.
Reset condition
On reset, the droop measurement source is set to the first channel 1 or 4 available.
CHAN
4
:SOUR
:DRO
Space
?
ACQ
ALLRF
1
NONE
ACQ:DRO:SOUR CHAN1
This command sets the droop measurement
source to channel 1.