3-6
Keysight B1505A Configuration and Connection Guide
N1265A Connection Guide
Input Connection
Table 3-2
To Connect between B1505A and N1265A, without HVMCU and UHVU
B1505A terminals
Required cables
N1265A terminals
Interlock
16493J Interlock cable, 3 m or 1.5 m, 1 ea.
Interlock
1
GNDU
16493L GNDU cable, 3 m or 1.5 m, 1 ea.
GNDU
2
HVSMU
Force
16493T HVSMU cable, 3 m or 1.5 m, 1 ea.
Selector Input
HVSMU
3
HPSMU
or
MPSMU
Force
16494A Triaxial cable, 3 m or 1.5 m, 1 ea., for the non-Kelvin
connection, connect it between the Force connectors.
For the Kelvin connection, prepare additional one more cable and
connect it between the Sense connectors.
Selector
Input
SMU
Force
Sense
Sense
MCSMU
4
Force
16494A Triaxial cable, 3 m or 1.5 m, 1 ea.
UHC
Input
V Control
Force
Sense
16494A Triaxial cable, 3 m or 1.5 m, 1 ea.
Sense
MCSMU
4
Force
16494A Triaxial cable, 3 m or 1.5 m, 1 ea.
UHC
Input
I Control
Force
Sense
16494A Triaxial cable, 3 m or 1.5 m, 1 ea.
Sense
MCSMU
4
Force
16494A Triaxial cable, 3 m or 1.5 m, 1 ea.
Gate
Force
Sense
16494A Triaxial cable, 3 m or 1.5 m, 1 ea.
Sense
MCSMU
or
HPSMU
or
MPSMU
Force
To connect MCSMU, use two 16494A cables, 3 m or 1.5 m.
To connect HP/MPSMU, use N1261A-001 protection adapter and
four 16494A triaxial cables for Kelvin connection or two 16494A
cables for non-Kelvin connection. Recommended cable length is
1.5 m. See
"To Connect Protection Adapter" on page 5-23
for
protection adapter.
SMU
1/2/3
See
.
[1]/[3]
/[5]
Sense
[2]/[4]
/[6]
HCSMU
or
DHCSMU
Force
For HCSMU, 16493S HCSMU cable, 3 m or 1.5 m, 1 ea.,
N1254A-103 adapter for Force, and N1254A-517 adapter for
Sense
For DHCSMU, 16493S HCSMU cable, 3 m or 1.5 m, 1 ea.,
16493S-021 Dual HCSMU adapter, N1254A-103 adapter for
Force, and N1254A-517 adapter for Sense. See
for Dual HCSMU adapter.
SMU 3
[5]
Sense
[6]
MFCMU
Hpot
N1300A-001 CMU cable 1 ea., N1260A high voltage bias-tee 1
ea., and N1254A-518 SHV(plug)-SHV(plug) cable 2 ea. See
Connect High Voltage Bias Tee" on page 5-25
It is not needed to connect the ground wire extended from the
CMU cable.
Bias Tee
High
Hcur
Lcur
Low
Lpot
Summary of Contents for B1505A
Page 3: ......
Page 9: ...1 Configuration Guide ...
Page 83: ...2 N1259A Connection Guide ...
Page 107: ...3 N1265A Connection Guide ...
Page 133: ...4 N1272A and N1273A Connection Guide ...
Page 149: ...5 Connection Guide for Wafer Prober and Your Own Test Fixture ...
Page 203: ...6 Accessory Dimensions ...
Page 219: ...7 Connection and Ordering Examples ...
Page 297: ......