10. SOFTWARE RAID1
10-29
10.6.3 Status display function
The status display function displays the current software RAID status. The software RAID status
is shown on the menu window in the Software RAID utility startup process.
This function displays information shown in the table below.
Table 10-2 Array Status and Drive Status
Item Value
Meaning
Array Status
OPTIMAL
The array has redundancy and both drives are working in
the ONLINE state.
OPTIMAL
(MEDIA ERROR)
A media error is present in the OPTIMAL state.
DEGRADE
The array does not have redundancy and is in degraded
operation. Either drive is working in the ONLINE state.
DEGRADE
(MEDIA ERROR)
A media error is present in the DEGRADE state.
UNKNOWN
The array status is unknown. The drive status is unknown,
or no array has been created.
Drive1 Status
Drive2 Status
ONLINE
Drives are working normally.
OFFLINE
Disconnection occurred (due to an HDD failure).
NOT CONNECTED
No drive is mounted in the drive bay.
NEW
A new drive that has not been used in model B is mounted.
REBUILD
Rebuilding in progress.
INCOMPLETE
DATA
Disconnection occurred (as a result of data mismatch due to
a power failure or reset).
ERROR
A drive failed during access.
Summary of Contents for HF-W2000
Page 44: ...This Page Intentionally Left Blank ...
Page 72: ...This Page Intentionally Left Blank ...
Page 102: ...This Page Intentionally Left Blank ...
Page 133: ......
Page 134: ...This Page Intentionally Left Blank ...
Page 176: ...This Page Intentionally Left Blank ...
Page 204: ...This Page Intentionally Left Blank ...
Page 245: ...This Page Intentionally Left Blank ...
Page 279: ...This Page Intentionally Left Blank ...