9. TROUBLESHOOTING
9-33
9.6.2 Displaying a hardware status code
A hardware status code is displayed when an error occurs in the hardware during system
operation.
When the hardware status code is displayed, the RAS status lamp (red) in the status
indication LEDs is lit.
Table 9-6 Hardware Status Code and Cause/Action
Status code
Cause
Action
11
Rotation of the power supply fan is abnormal.
Read the description in “9.2.2 (1)”
and take action accordingly.
12
Rotation of the system fan is abnormal.
13
Rotation of the CPU fan is abnormal.
21
The temperature is abnormal.
Read the description in “9.2.2 (1)”
and take action accordingly.
31
Failure is predicted for the drive in drive bay 1.
We recommend you back up the
data and replace the drive.
32
Failure is predicted for the drive in drive bay 2.
41
(*1)
The drive bay1 is abnormal.
Read the description of "10.4.2"
and replace an HDD.
42
(*1)
The drive bay2 is abnormal.
4C
RAID status is unknown (RAS software could
not get the RAID status.)
Contact your system administrator
or maintenance personnel.
4D
(*2)
Media error is occurred on RAID.
Read the description of RAS
FEATURES MANUAL "2.8.2"
and take action accordingly.
(*1) This code is also displayed during rebuilding.
(*2) This code is not displayed in default setting. Read the description of RAS FEATURES MANUAL
“2.8.2” when you want to display this code.
< NOTE >
If a code other than one of the above is displayed, contact the system administrator
or maintenance personnel.
Summary of Contents for HF-W2000
Page 44: ...This Page Intentionally Left Blank ...
Page 72: ...This Page Intentionally Left Blank ...
Page 102: ...This Page Intentionally Left Blank ...
Page 133: ......
Page 134: ...This Page Intentionally Left Blank ...
Page 176: ...This Page Intentionally Left Blank ...
Page 204: ...This Page Intentionally Left Blank ...
Page 245: ...This Page Intentionally Left Blank ...
Page 279: ...This Page Intentionally Left Blank ...