4-2-4 Adjustment of needle position (Left and Right)
Adjust for 1
st
head
If you change 1
st
head position, you need to confirm head
position other all head.
1. Remove the cover of Needle bar change unit.
Cover
2. Push the Moving head right and left for confirm should not
have a play the Cam. If you have a play the cam, please
refare [ 4-3-1 Check / Adjustment of needle bar change
unit ]. Cam
3. Move the head to 8th needle and remove Detecting Cover
and Thread Detecting Board of 1st head and loose screw
for needle bar change unit.
< Note >
Please turn off machine power.
Detecting cover
Thread detecting board
Screw for needle bar change unit inside the beem.
4. Turn the knob and stop at a needle stop position. Then
down needle till needle point to needle plate face. You can
move the Moving head with Needle bar change unit right
and left for adjust needle position to cemter to needle plate
hole.
Needle Needle hole of needle plate
Summary of Contents for HCR3-1502
Page 1: ... Maintenance Manual for Embroidery Machine HCR3E SERIES Version 1 2 HappyJapan Inc ...
Page 104: ...105 4 7 3 Adjustment of timing detecting unit 8 Finally put the cover back on ...
Page 107: ...107 ...
Page 172: ...172 E7 Electric system diagram E7 1 Pulse motor driver PMD wiring ...
Page 173: ...173 E7 2 Pulse motor driver PMD setup ...
Page 174: ...174 E7 3 Inverter wiring ...
Page 175: ...175 E7 4 Electrical connection diagram ...
Page 176: ...176 ...
Page 177: ...177 ...
Page 178: ...178 E7 5 List of electrical connection diagram ...
Page 179: ...179 ...
Page 180: ...180 E7 6 Explanation of function clrcuit board HCD8122 LCD CE MX Board Ass y ...
Page 181: ...181 HCD8116 TP SW Circuit Board Ass y CN No Function CN1 Switch output LED input ...