14
2-3, 2-4 Setting up the machine
2-3 Removal of stopper
(1) Loosen the screw and remove the red shipping collars that
are equipped on the both side of the guide bar.
(2) Remove head stopper.
< Note >
Number of head stopper is depending on model.
Head stopper
2-4 Check of needle position
(1).
Turn power switch ON, and
enter user maintenance
mode.
Refer to [ 5 User maintenance mode ]
(2) Remove bobbin case.
(3) With help of user maintenance mode, please move needle
bar down and confirm needle position is center of needle
hole on needle plate.
< Note >
Please move needle bar slowly
< Note >
Please check position of 8
th
needle, then check
1
st
and 15
th
needle
.
Needle Needle hole of needle plate
Summary of Contents for HCR3-1502
Page 1: ... Maintenance Manual for Embroidery Machine HCR3E SERIES Version 1 2 HappyJapan Inc ...
Page 104: ...105 4 7 3 Adjustment of timing detecting unit 8 Finally put the cover back on ...
Page 107: ...107 ...
Page 172: ...172 E7 Electric system diagram E7 1 Pulse motor driver PMD wiring ...
Page 173: ...173 E7 2 Pulse motor driver PMD setup ...
Page 174: ...174 E7 3 Inverter wiring ...
Page 175: ...175 E7 4 Electrical connection diagram ...
Page 176: ...176 ...
Page 177: ...177 ...
Page 178: ...178 E7 5 List of electrical connection diagram ...
Page 179: ...179 ...
Page 180: ...180 E7 6 Explanation of function clrcuit board HCD8122 LCD CE MX Board Ass y ...
Page 181: ...181 HCD8116 TP SW Circuit Board Ass y CN No Function CN1 Switch output LED input ...