COMMAND SYNTAX
246
Example
:SOURce:CURRent:MODE?
Command
:SOURce[1]:VOLTage:MODE <name>
Function
This Command is used to select the DC sourcing
mode for the V-Source. The three modes are
explained as follows:
FIXed — In this DC sourcing mode, the specified
source will output a fixed level. Use the :RANGe
and :AMPLitude Commands to specify the fixed
source level.
LIST — In this mode, the source will output levels
that are specified in a list.
SWEep — In this mode, the source will perform a
voltage, current or memory sweep.
<name> = FIXed Select fixed sourcing mode
LIST Select list sourcing mode
SWEep Select sequence sourcing mode
Example
:SOURce:VOLTage:MODE FIXed
Command
:SOURce[1]:VOLTage:MODE?
Function
Query DC sourcing mode
Example
:SOURce:VOLTage:MODE?
Command
:SOURce[1]:CURRent:RANGe <n>
Function
This Command is used to manually select the range
for the I-Source. Range is selected by specifying the
approximate source magnitude that you will be
using. The instrument will then go to the lowest
range that can accommodate that level.
As listed in the “Parameters,” you can also use the
MINimum, MAXimum and DEFault parameters to