GSM-20H10 User Manual
91
Parameter Settings Of Calculation Function
Power
This calculation function uses the measurement
voltage value multiplying the measurement current
value to obtain the Power measurement reading, and
the unit of the displayed value is watts.
Operation steps:
a
Press the F2 (Measure) key to enter the Measure
interface, select the required source value(V-
Source or I-Source), and then long press the F2
(Measure) key to display the calculation function
interface.
b
Press the F1 (Power) key to select the Power
function (the font turns red).
c
Press F6 (Cancel) to return to the Measure
interface.
d
Press the 0/M key to enter the caculation
interface, the POWER symbol appears in the
display area, indicating that the POWER
caculation is performed.
e
Finally, turn on the Output key, and the
measurment power value will be displayed.
NOTE: If it is already in the calculation
Measure interface before setting calculation
parameters, press the F6 (Cancel) key to return to
the calculation Measure interface and do not need
to press the 0/M key.
For example, when the GSM is connected to a 2MΩ
pure resistor, Isrc is set to 1uA, and Cmpl is set to
2.1V, the Power measurement reading is shown in
the following figure: