3-152
UR SERIES – COMMUNICATIONS GUIDE
SCL LOG MESSAGES
CHAPTER 3: IEC 61850 COMMUNICATION
3
Number of RUNTIME_TYPE elements = 0. Cannot create type for LNodeType id=<logical node>
RUNTIME type elements are data attributes.
This message is logged when a new runtime type cannot be created for a logical node.
Type creation error: name <type name> already in use
RUNTIME type elements are data attributes.
This message is logged when a new runtime type was detected but was found to be already in use.
mvl_type_id_create error: type array full
RUNTIME type elements are data attributes.
This message is logged when the number of data attributes exceeds the limit.
Error setting leaf functions for LNodeType id=<logical node>
This message is logged when unable to create read and write functions for each attribute in logical node.
Could not create type for LNodeType id = <logical node>
This message is logged when lnType cannot be created due to type id being < 0.
Logical Devices already created for this SCL file. Cannot create again.
This message is logged when duplicate logical device creation is requested due to configuration errors in the CID file.
Cannot find type=<lnType> for logical node=<logical node>
This message is logged when lnType is not found for a logical node in the CID file.
Error creating VAR <logical node>: domain <logical domain> not found
This message is logged when there is an error constructing object name from LD and LN information.
Cannot create LN=<logical node> in LD=<logical device>
This message is logged when logical node cannot be created in logical device.
Cannot find GSE element for GOOSE Control <gcb name>
This message is logged when unable to find the GSE element specified in the GOOSE control block in the CID file.
Constructed ObjectReference would be too long for <object name>
This message is logged when the specified object reference string is longer than supported.
Attribute Datset not found so not initialized.
This message is logged when GOOSE datset was not found.
Attribute GoID not found so not initialized.
This message is logged when GOOSE ID was not found.
Attribute ConfRev not found so not initialized.
This message is logged when GOOSE ConfRev was not found.
Attribute FixedOffs not found so not initialized.
This message is logged when GOOSE FixedOffs was not found.
Summary of Contents for UR series
Page 5: ...TABLE OF CONTENTS UR SERIES COMMUNICATIONS GUIDE v INDEX...
Page 6: ...vi UR SERIES COMMUNICATIONS GUIDE TABLE OF CONTENTS...
Page 20: ...1 14 UR SERIES COMMUNICATIONS GUIDE FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1...
Page 216: ...2 196 UR SERIES COMMUNICATIONS GUIDE MEMORY MAP CHAPTER 2 MODBUS COMMUNICATION 2...
Page 428: ...A 2 UR SERIES COMMUNICATIONS GUIDE REVISION HISTORY APPENDIX A MISCELLANEOUS A...