2-134
UR SERIES – COMMUNICATIONS GUIDE
MEMORY MAP
CHAPTER 2: MODBUS COMMUNICATION
2
"
A842
POTT1 1P Rx4
0 to 4294967295
---
1
F300
0
"
A844
POTT1 1P Target
0 to 2
---
1
F109
0 (Self-reset)
"
A845
POTT1 1P Event
0 to 1
---
1
F102
0 (Disabled)
"
A846
POTT1 1P Echo Condition
0 to 4294967295
---
1
F300
0
"
A848
POTT1 1P Scheme Block
0 to 4294967295
---
1
F300
0
"
A84A
POTT1 1P OC Fwd2
0 to 4294967295
---
1
F300
0
"
A84C
POTT1 1P OC Fwd2
0 to 4294967295
---
1
F300
0
"
A84E
Reserved (22 items)
0 to 1
---
1
F001
0
Pilot Blocking 1 (1P) (Read/Write Setting)
D60, L90
A864
Blocking 1 Scheme 1P Function
0 to 1
---
1
F102
0 (Disabled)
"
A865
Blocking 1 Scheme 1P Block
0 to 4294967295
---
1
F300
0
"
A867
Block 1 1P Rx Coord Pickup Delay
0 to 65.535
s
0.001 F001
10
"
A868
Block 1 1P Transient Block Pickup Delay
0 to 65.535
s
0.001 F001
30
"
A869
Block 1 1P Transient Block Reset Delay
0 to 65.535
s
0.001 F001
90
"
A86A
Blocking 1 Scheme 1P Seal in Delay
0 to 65.535
s
0.001 F001
0
"
A86B
Blocking 1 Scheme 1P Dir Fwd 1
0 to 4294967295
---
1
F300
0
"
A86D
Blocking 1 Scheme 1P Dir Fwd 2
0 to 4294967295
---
1
F300
0
"
A86F
Blocking 1 Scheme 1P Dir Fwd 3
0 to 4294967295
---
1
F300
0
"
A871
Blocking 1 Scheme 1P Dir Rev 1
0 to 4294967295
---
1
F300
0
"
A873
Blocking 1 Scheme 1P Dir Rev 2
0 to 4294967295
---
1
F300
0
"
A875
Blocking 1 Scheme 1P Dir Rev 3
0 to 4294967295
---
1
F300
0
"
A877
Blocking 1 Scheme 1P Force Tx Stop 1
0 to 4294967295
---
1
F300
0
"
A879
Blocking 1 Scheme 1P Force Tx Stop 2
0 to 4294967295
---
1
F300
0
"
A87B
Blocking 1 Scheme 1P Comm Bits
0 to 2
---
1
F198
0 (1)
"
A87C
Blocking 1 Scheme 1P Rx1
0 to 4294967295
---
1
F300
0
"
A87E
Blocking 1 Scheme 1P Rx2
0 to 4294967295
---
1
F300
0
"
A880
Blocking 1 Scheme 1P Rx3
0 to 4294967295
---
1
F300
0
"
A882
Blocking 1 Scheme 1P Rx4
0 to 4294967295
---
1
F300
0
"
A884
Blocking 1 1P Target
0 to 2
---
1
F109
0 (Self-reset)
"
A885
Blocking 1 1P Event
0 to 1
---
1
F102
0 (Disabled)
Frequency Rate of Change (Read/Write Setting) (4 Modules)
D60, F60, G30,
G60, L90, N60,
T60
A900
Frequency Rate of Change 1 Function
0 to 1
---
1
F102
0 (Disabled)
"
A901
Frequency Rate of Change 1 OC
Supervision
0 to 30
pu
0.001 F001
200
"
A902
Frequency Rate of Change 1 Min
20 to 80
Hz
0.01
F001
4500
"
A903
Frequency Rate of Change 1 Max
20 to 80
Hz
0.01
F001
6500
"
A904
Frequency Rate of Change 1 Pickup Delay 0 to 65.535
s
0.001 F001
0
"
A905
Frequency Rate of Change 1 Reset Delay
0 to 65.535
s
0.001 F001
0
"
A906
Frequency Rate of Change 1 Block
0 to 4294967295
---
1
F300
0
"
A908
Frequency Rate of Change 1 Target
0 to 2
---
1
F109
0 (Self-reset)
"
A909
Frequency Rate of Change 1 Events
0 to 1
---
1
F102
0 (Disabled)
"
A90A
Frequency Rate of Change 1 Source
0 to 5
---
1
F167
0 (SRC 1)
"
A90B
Frequency Rate of Change 1 Trend
0 to 2
---
1
F224
0
(Increasing)
"
A90C
Frequency Rate of Change 1 Pickup
0.1 to 15
Hz/s
0.01
F001
50
Products
Address Register name
Range
Units
Step
Format
Default
Summary of Contents for UR series
Page 5: ...TABLE OF CONTENTS UR SERIES COMMUNICATIONS GUIDE v INDEX...
Page 6: ...vi UR SERIES COMMUNICATIONS GUIDE TABLE OF CONTENTS...
Page 20: ...1 14 UR SERIES COMMUNICATIONS GUIDE FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1...
Page 216: ...2 196 UR SERIES COMMUNICATIONS GUIDE MEMORY MAP CHAPTER 2 MODBUS COMMUNICATION 2...
Page 428: ...A 2 UR SERIES COMMUNICATIONS GUIDE REVISION HISTORY APPENDIX A MISCELLANEOUS A...