2-116
UR SERIES – COMMUNICATIONS GUIDE
MEMORY MAP
CHAPTER 2: MODBUS COMMUNICATION
2
"
8BA2
...Repeated for Digital Element 20
"
8BB8
...Repeated for Digital Element 21
"
8BCE
...Repeated for Digital Element 22
"
8BE4
...Repeated for Digital Element 23
"
8BFA
...Repeated for Digital Element 24
"
8C10
...Repeated for Digital Element 25
"
8C26
...Repeated for Digital Element 26
"
8C3C
...Repeated for Digital Element 27
"
8C52
...Repeated for Digital Element 28
"
8C68
...Repeated for Digital Element 29
"
8C7E
...Repeated for Digital Element 30
"
8C94
...Repeated for Digital Element 31
"
8CAA
...Repeated for Digital Element 32
"
8CC0
...Repeated for Digital Element 33
"
8CD6
...Repeated for Digital Element 34
"
8CEC
...Repeated for Digital Element 35
"
8D02
...Repeated for Digital Element 36
"
8D18
...Repeated for Digital Element 37
"
8D2E
...Repeated for Digital Element 38
"
8D44
...Repeated for Digital Element 39
"
8D5A
...Repeated for Digital Element 40
"
8D70
...Repeated for Digital Element 41
"
8D86
...Repeated for Digital Element 42
"
8D9C
...Repeated for Digital Element 43
"
8DB2
...Repeated for Digital Element 44
"
8DC8
...Repeated for Digital Element 45
"
8DDE
...Repeated for Digital Element 46
"
8DF4
...Repeated for Digital Element 47
"
8E0A
...Repeated for Digital Element 48
Trip Bus (Read/Write Setting) (6 Modules)
All
8ED0
Trip Bus 1 Function
0 to 1
---
1
F102
0 (Disabled)
"
8ED1
Trip Bus 1 Block
0 to 4294967295
---
1
F300
0
"
8ED3
Trip Bus 1 Pickup Delay
0 to 600
s
0.01
F001
0
"
8ED4
Trip Bus 1 Reset Delay
0 to 600
s
0.01
F001
0
"
8ED5
Trip Bus 1 Input (16 items)
0 to 4294967295
---
1
F300
0
"
8EF5
Trip Bus 1 Latching
0 to 1
---
1
F102
0 (Disabled)
"
8EF6
Trip Bus 1 Reset
0 to 4294967295
---
1
F300
0
"
8EF8
Trip Bus 1 Target
0 to 2
---
1
F109
0 (Self-reset)
"
8EF9
Trip Bus 1 Events
0 to 1
---
1
F102
0 (Disabled)
"
8EFA
Reserved (8 items)
0 to 1
---
1
F001
0
"
8F02
...Repeated for Trip Bus 2
"
8F34
...Repeated for Trip Bus 3
"
8F66
...Repeated for Trip Bus 4
"
8F98
...Repeated for Trip Bus 5
"
8FCA
...Repeated for Trip Bus 6
FlexElement (Read/Write Setting) (8 or 16 Modules)
All except B90
9000
FlexElement 1 Function
0 to 1
---
1
F102
0 (Disabled)
Products
Address Register name
Range
Units
Step
Format
Default
Summary of Contents for UR series
Page 5: ...TABLE OF CONTENTS UR SERIES COMMUNICATIONS GUIDE v INDEX...
Page 6: ...vi UR SERIES COMMUNICATIONS GUIDE TABLE OF CONTENTS...
Page 20: ...1 14 UR SERIES COMMUNICATIONS GUIDE FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1...
Page 216: ...2 196 UR SERIES COMMUNICATIONS GUIDE MEMORY MAP CHAPTER 2 MODBUS COMMUNICATION 2...
Page 428: ...A 2 UR SERIES COMMUNICATIONS GUIDE REVISION HISTORY APPENDIX A MISCELLANEOUS A...