CHAPTER 4: DNP COMMUNICATION
DEVICE PROFILE DOCUMENT
UR SERIES – COMMUNICATIONS GUIDE
4-3
4
Sends/executes control operations
WRITE Binary Outputs
Never
Always
Sometimes
Configurable
SELECT/OPERATE
Never
Always
Sometimes
Configurable
DIRECT OPERATE
Never
Always
Sometimes
Configurable
DIRECT OPERATE – NO ACK
Never
Always
Sometimes
Configurable
Count
>
1
Never
Always
Sometimes
Configurable
Pulse On
Never
Always
Sometimes
Configurable
Pulse Off
Never
Always
Sometimes
Configurable
Latch On
Never
Always
Sometimes
Configurable
Latch Off
Never
Always
Sometimes
Configurable
Queue
Never
Always
Sometimes
Configurable
Clear Queue
Never
Always
Sometimes
Configurable
Explanation of ‘Sometimes’:
Object 12 points are mapped to UR Virtual Inputs. The persistence of Virtual Inputs is
determined by the
VIRTUAL INPUT X TYPE
settings. Both “Pulse On” and “Latch On” operations perform the same func-
tion in the UR; that is, the appropriate Virtual Input is put into the “On” state. If the Virtual Input is set to “Self-Reset”, it
will reset after one pass of FlexLogic. The On/Off times and Count value are ignored. “Pulse Off” and “Latch Off” oper-
ations put the appropriate Virtual Input into the “Off” state. “Trip” and “Close” operations both put the appropriate Vir-
tual Input into the “On” state.
Reports Binary Input Change Events when no
specific variation requested
Never
Only time-tagged
Only non-time-tagged
Configurable
Reports time-tagged Binary Input Change Events when no
specific variation requested
Never
Binary Input Change With Time
Binary Input Change With Relative Time
Configurable (attach explanation)
Sends unsolicited responses
Never
Configurable
Only certain objects
Sometimes (attach explanation)
ENABLE/DISABLE unsolicited Function codes
supported
Sends static data in unsolicited responses
Never
When Device Restarts
When Status Flags Change
No other options are permitted.
Default counter object/variation
No Counters Reported
Configurable (attach explanation)
Default Object:20
Default Variation:1
Point-by-point list attached
Counters roll over at
No Counters Reported
Configurable (attach explanation)
16 Bits (Counter 8)
32 Bits (Counters 0 to 7, 9)
Other Value: _____
Point-by-point list attached
Sends multi-fragment responses
Yes
No
Summary of Contents for UR series
Page 5: ...TABLE OF CONTENTS UR SERIES COMMUNICATIONS GUIDE v INDEX...
Page 6: ...vi UR SERIES COMMUNICATIONS GUIDE TABLE OF CONTENTS...
Page 20: ...1 14 UR SERIES COMMUNICATIONS GUIDE FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1...
Page 216: ...2 196 UR SERIES COMMUNICATIONS GUIDE MEMORY MAP CHAPTER 2 MODBUS COMMUNICATION 2...
Page 428: ...A 2 UR SERIES COMMUNICATIONS GUIDE REVISION HISTORY APPENDIX A MISCELLANEOUS A...