background image

Iseo  Serrature  s.p.a 
Via  San  Girolamo  13 
25055  Pisogne  (BS) 
ITALY
Tel.  +39  0364  8821 
[email protected]

Non contractual document. Subject to change. Cod. KW14341 - 28/06/2022

V364 Relay Installation Guide(EN) - © 2022  Iseo Serrature S.p.a.

WARNINGS

Read this manual prior to use the device in order to ensure a safe and proper use.

Preserve this manual as future reference.

The installation and maintanance of the device must be carried out by qualified technical staff, adequately 
trained by ISEO.
The instructions should be carefully followed during installation. These instructions and any maintenance 
instructions should be passed on by the installer to the user.

No modifications of any kind are permitted, except for those described in these instructions.

The product must be destined only for the use for which it is expressly designed and therefore as a 
credential reader for civil and industrial locations. Any other use is considered improper and dangerous.

The electrical connection must be made according to the constructor's instructions and respecting the
regulations in force.

In the event of a failure and/or poor operation, remove the power supply using the main switch and do not
tamper with it. For all repairs, exclusively contact a technical assistance center authorized by the constructor.

Disconnect the power supply before carrying out any technical service that involves opening or accessing 
the internal parts of the product.

1. TECHNICAL DATA

PRODUCT:

V364 Relay.

APPLICATION:

To open any electrical device.

MODELS:

1. V364 Relay (with built in BLE module).

2. V364 Relay with remote BLE module.*

HOUSING:

 - To e fixed to the wall.
 - To be placed inside a box.  
 - On a DIN35 Rail with the additional mounting clip.

OPERATING TEMPERATURES:

OUTPUTS:

- 1 Power Relay: RELAY
     NO contact (normally open) 
     30VDC/VAC - 5A max with RESISTIVE loads

 - Working and storage: -25°C/+70°C. 
 - H.R.: Max. 95% without condensing. 

2. MODELS AND DIMENSIONS

53 mm

35 mm

109 mm

65 mm

15 mm

26 mm

V364 Relay (with built in BLE)

V364 Relay with remote BLE

V364 Relay 

V364 RELAY

RELAY: 5A - 30VDC/VAC

OUTPUT: 1A - 30VDC/VAC

MADE IN ITALY
Power IN

10 - 30VDC (2W)
12 - 24VAC (4VA)

VDC

MASTER

REX+

REX

IN

GND

COM

NO

COM

SW1

RELAY

OUT

IN

REX

Power

V364

Power IN

REX

INPUT

RELAY

OUTPUT

NO

SER
AUX

REMOTE ANT.

Remote Bluetooth Module

V364 RELAY

MADE IN ITALY

Max cable length = 3mt
IP53

Remote BLE 

82 mm

3. PRINCIPLE OF WORKING  

POWER IN

On average

10mt*

*Phone Bluetooth trasmission total distance may vary 

depending on V364 Relay location and surrounding 

environment. For example walls, doors, glazed surfaces 

can reduce or stop the communication between phone 

and V364 Relay.

V364 RELAY

RELAY: 5A - 30VDC/VAC

OUTPUT: 1A - 30VDC/VAC

MADE IN ITALY
Power IN

10 - 30VDC (2W)
12 - 24VAC (4VA)

VDC

MASTER

REX+

REX

IN

GND

COM

NO

COM

SW1

RELAY

OUT

IN

REX

Power

V364

Power IN

REX

INPUT

RELAY

OUTPUT

NO

SER
AUX

REMOTE ANT.

4. ELECTRICAL CONNECTIONS

V364 RELAY

RELAY: 5A - 30VDC/VAC

OUTPUT: 1A - 30VDC/VAC

MADE IN ITALY
Power IN

10 - 30VDC (2W)
12 - 24VAC (4VA)

VDC

MASTER

REX+

REX

IN

GND

COM

NO

COM

SW1

RELAY

OUT

IN

REX

Power

V364

Power IN

REX

INPUT

RELAY

OUTPUT

NO

SER
AUX

REMOTE ANT.

Power IN

RELAY

Remote BLE connector 
available only with V364 
Relay with remote BLE. 

INPUTS
Power IN

Description
Power supply

OUTPUTS
RELAY

Description
5A power relay NO

For INPUTS and OUTPUTS 
technical data see Box 1.

5. CONNECTION EXAMPLE: V364 RELAY OPENS AN ELECTRIC LOCK  

V364 RELAY

RELAY: 5A - 30VDC/VAC

OUTPUT: 1A - 30VDC/VAC

MADE IN ITALY
Power IN

10 - 30VDC (2W)
12 - 24VAC (4VA)

VDC

MASTER

REX+

REX

IN

GND

COM

NO

COM

SW1

RELAY

OUT

IN

REX

Power

V364V

Power IN

REX

INPUT

RELAY

OUTPUT

NO

SER
AUX

REMOTE ANT.

230VAC

Power 

supply

Electric lock

6. CONNECTION EXAMPLE: V364 RELAY OPENS MULTIBLINDO eMOTION  

V364 RELAY

RELAY: 5A - 30VDC/VAC

OUTPUT: 1A - 30VDC/VAC

MADE IN ITALY
Power IN

10 - 30VDC (2W)
12 - 24VAC (4VA)

VDC

MASTER

REX+

REX

IN

GND

COM

NO

COM

SW1

RELAY

OUT

IN

REX

Power

V364

Power IN

REX

INPUT

RELAY

OUTPUT

NO

SER
AUX

REMOTE ANT.

230VAC

Power 

supply

Multiblindo 

eMotion

PACKAGE CONTENT:

- 1 V364 Relay
- 1 DIN rail mounting clip with screws
- 1 BLE remote module with cable
  (only for model 2)*
- 1 Installation guide (EN/IT)

COMMUNICATION INTERFACE:

Bluetooth 5.0 - Frequency 2,40 - 2,4835 GHz

Maximum power: 5,25 mW

POWER SUPPLY:

10

÷30 VDC (2W)

12

÷24 VAC (4VA)

If the power supply has a power greater than 90W and it’s not SELV type (Safety Extra Low Voltage - double 

insulation, overcurrent and short-circuit protected), it must be provided upstream of the lock power input, an 

appropriate protection switch (circuit breaker), or delayed fuse with protection value equal to 1A.

Output NC

Output NO (default)

*

V364 RELAY

INSTALLATION GUIDE (EN)

EC Declarations of conformity available at:

https://www.iseo.com/it/en/download

ULTIMATE ACCESS

  T E C H N O L O G I E S

ULTIMATE ACCESS

  T E C H N O L O G I E S

ULTIMATE ACCESS

  T E C H N O L O G I E S

ULTIMATE ACCESS

  T E C H N O L O G I E S

ULTIMATE ACCESS

  T E C H N O L O G I E S

ULTIMATE ACCESS

  T E C H N O L O G I E S

ULTIMATE ACCESS

  T E C H N O L O G I E S

Summary of Contents for V364

Page 1: ...m 3 PRINCIPLE OF WORKING POWER IN On average 10mt Phone Bluetooth trasmission total distance may vary depending on V364 Relay location and surrounding environment For example walls doors glazed surfaces can reduce or stop the communication between phone and V364 Relay V364 RELAY RELAY 5A 30VDC VAC OUTPUT 1A 30VDC VAC MADE IN ITALY Power IN 10 30VDC 2W 12 24VAC 4VA VDC MASTER REX REX IN GND COM NO ...

Page 2: ...Y OUTPUT NO SER AUX REMOTE ANT 230VAC Power supply 9 INSTALLATION ON THE WALL Wall fixing screws and plugs 4mm diameter supplied in the kit CRACK CRACK 10 INSTALLATION INSIDE A BOX 1 2 12 FIRST CONFIGURATION For the V364 Relay configuration read the V364 2 0 System Administrator Manual available at iseo com 11 INSTALLATION ON THE DIN RAIL 1 2 3 Lithium Battery CR2032 3V 3V CR2032 Lithium Risk of e...

Page 3: ...nza maggiore di 90W o non è di tipo SELV doppio isolamento e protetto da sovracorrenti e corto circuito deve essere previsto a monte dell ingresso di alimentazione della serratura un appropriato interruttore di protezione magnetotermico o fusibile ritardato con valore di protezione pari a 1A Alimentazione Leggere il manuale utente prima dell utilizzo del prodotto al fine di garantire un uso sicuro...

Page 4: ... con altra di tipo errato Smaltire separatamente le pile usate seguendo le disposizioni locali La sostituzione della pila deve essere effettuata da personale tecnico qualificato V364 RELAY RELAY 5A 30VDC VAC OUTPUT 1A 30VDC VAC MADE IN ITALY Power IN 10 30VDC 2W 12 24VAC 4VA VDC MASTER REX REX IN GND COM NO COM SW1 RELAY OUT IN REX Power V364 Power IN REX INPUT RELAY OUTPUT NO SER AUX REMOTE ANT V...

Reviews: