Level 2 FIP (Fault Isolation Procedure
5-100
FIP-2.19 Faulty ADC Solenoid
FIP-2.19 Faulty ADC Solenoid
FIP-2.19 Faulty ADC Solenoid
FIP-2.19 Faulty ADC Solenoid
Step
Check
Treatment
Yes
No
1
*Initial setting
Use of parts of non-EPSON specifications, improper mounting, damage, distortion, dirt,
adherence of foreign matter?
*Main parts to check
ADC SENSOR ASSY, MAIN HARNESS ASSY, MCU PWB
Replace and remount
the concerned part(s).
Go to step 2.
2
*ADC Solenoid power supply check
Is there 24VDC between P/J16-22PIN <=> P/J16-23PIN?
Go to step 3.
Go to FIP-2.2
3
*ADC Solenoid check
Is there a continuity (approx. 36
Ω
Ω
Ω
Ω
) between J16-22PIN <=> J16-23PIN?
Replace the MCU PWB. Go to step 4.
4
*MAIN HARNESS ASSY check
Is there a proper continuity between J16 <=> P81?
Replace the ADC
SOLENOID.
Replace the P/H
HARNESS ASSY.
Summary of Contents for AcuLaser C8500
Page 12: ......
Page 21: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Page 78: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 108: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 31 Figure 2 38 Xerographics II ...
Page 110: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 33 Figure 2 39 Development ...
Page 118: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 41 Figure 2 45 Drive ...
Page 120: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 43 Figure 2 46 Electrical ...
Page 153: ...C H A P T E R 3 DISASSEMBLY ASSEMBLY ADJUSTMENT ...
Page 269: ...C H A P T E R 4 DIAGNOSTICS ...
Page 353: ...C H A P T E R 5 TROUBLESHOOTING ...
Page 480: ...C H A P T E R 6 MAINTENANCE ...
Page 503: ...C H A P T E R 7 APPENDIX ...
Page 564: ......
Page 565: ......
Page 566: ......
Page 567: ......
Page 568: ......
Page 569: ......
Page 570: ......