Diagnostics
4-33
BCR_DC
0E
HVPS
<WARNING>
<CAUTION>
Do not check the BCR
output. Check the
signal.
(Check during
executing with code
[54]. HVPS can not
normaly without
executing with Analog
Output Test[02].)
Set BCR ON signal to
Low.
ROTARY_MOT
_POWER
10
ROTARY MOTOR
ASSY
Check the signal.(Not
operating)
[Turn it off
automatically in
10msec rest.]
Set ROARY MOTOR
HOLD signal to Low.
ROTARY_MOT
11
ROTARY MOTOR
ASSY
Check the signal.(Not
operating)
[Turn it off
automatically in
10msec rest.]
Set ROTARY MOTOR
ON signal to Low.
PATH_SOL
_PUSH
17
EXCHANGE
SOLENOID
Check by operational
sound that the
Solenoid is operating
and visually that the
EXCHANGE CHUTE
is operating.
(Though ON/ OFF is
repeated with 0.12sec/
1sec, only the first time
of the beginnings can
be checked.)
Set EXCHANGE
SOLENOID PUSH ON
signal to Low.
Table 4-10. Digital Output Test Device Code
Digital Output Test [DIAGSTART : [90 02 XX] , DIAGSTOP : [91 02 XX] ]
Code
Function Item
Name
(Hex)
When status data is
[High]
Check Method
PATH_SOL
_PULL
18
EXCHANGE
SOLENOID
Check by operational
sound that the
Solenoid is operating
and visually that the
EXCHANGE CHUTE
is operating.
(Though ON/ OFF is
repeated with 0.12sec/
1sec, only the first time
of the beginnings can
be checked.)
Set EXCHANGE
SOLENOID PULL ON
signal to Low.
OPT_DUP_PATH
_SOL_PUSH
19
DUP GATE SOLENOID
Check by operational
sound that the
Solenoid is operating
and visually that the
GATE‑DUPLEX
is
operating.
(Though ON/ OFF is
repeated with 0.12sec/
1sec, only the first time
of the beginnings can
be checked.)
Set DUP GATE
SOLENOID PUSH ON
signal to Low.
OPT_DUP_PATH
_SOL_PULL
1A
DUP GATE SOLENOID
Check by operational
sound that the
Solenoid is operating
and visually that the
GATE‑DUPLEX
is
operating.
(Though ON/ OFF is
repeated with 0.12sec/
1sec, only the first time
of the beginnings can
be checked.)
Set DUP GATE
SOLENOID PULL ON
signal to Low.
Table 4-10. Digital Output Test Device Code
Digital Output Test [DIAGSTART : [90 02 XX] , DIAGSTOP : [91 02 XX] ]
Code
Function Item
Name
(Hex)
When status data is
[High]
Check Method
Summary of Contents for AcuLaser C8500
Page 12: ......
Page 21: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Page 78: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 108: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 31 Figure 2 38 Xerographics II ...
Page 110: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 33 Figure 2 39 Development ...
Page 118: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 41 Figure 2 45 Drive ...
Page 120: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 43 Figure 2 46 Electrical ...
Page 153: ...C H A P T E R 3 DISASSEMBLY ASSEMBLY ADJUSTMENT ...
Page 269: ...C H A P T E R 4 DIAGNOSTICS ...
Page 353: ...C H A P T E R 5 TROUBLESHOOTING ...
Page 480: ...C H A P T E R 6 MAINTENANCE ...