EPSON AcuLaser C8500
Revision C
APPENDIX
Wiring Diagrams and Signal Information
7-44
PROCESS MOTOR ASSY description.
Motor type: Permanent magnet magnetic field DC servomotor
Number of poles: 3-phase, 8-poles
Motor control speed: 1735.358rpm ± 0.5% (standard speed),
867.679rpm ± 0.5% (half speed)
578.453rpm ± 0.5% (1/3 speed)
Direction of rotation: Counterclockwise direction
(as viewed from rear of printer)
Rotation fault detection: Detects abnormality when a variation in control
speed of 6.25% or greater occurs.
P/H MOTOR ASSY description.
Motor type: Permanent magnet magnetic field DC servomotor
Number of poles: 3-phase, 8- poles
Motor control speed: 1667rpm ± 0.5% (standard speed), 833.5rpm ±
0.5% (half speed) 555.667rpm (1/3 speed)
Direction of rotation: CCounterclockwise direction (as viewed from rear
of printer)
Rotation fault detection: Detects abnormality when a variation in control
speed of 6.25% or greater occurs. (P/H
MOT FAIL signal is “High”.)
FUSER MOTOR ASSY description.
Motor type: Permanent magnet magnetic field DC servomotor
Motor control speed: 1667rpm ± 0.5% (standard speed) 833.5rpm ±
0.5% (half speed)
555.667rpm ± (1/3 speed)
Direction of rotation: Counterclockwise direction
(as viewed from rear of printer)
Rotation fault detection: Detects abnormality when a variation in control
speed of 6.25% or greater occurs. (FUSER
FAIL signal is “High”.)
BTR CAM SOLENOID coil resistance: 220 ± 10% (20
o
C
)
Table 7-12. Signal Description -
§
§
§
§
6
Signal line
Description
TR0-M SENSED(L) 5VDC
TR mark detection signal for IBT belt ASSY issued by
the TR0 SENSOR.
P/H MOT FAIL(H) 5VDC
Fail detection signal for P/H MOTOR ASSY. (High:
Abnormal, Low: Normal)
FUSER FAIL(H) 5VDC
Fail detection signal for FUSER MOTOR ASSY. (High:
Abnormal, Low: Normal)
MOT ON(L) 24VDC
On/off control signal for P/H MOTOR ASSY and
FUSER MOTOR ASSY.
MOT CLOCK
Clock output signal for P/H MOTOR ASSY and FUSER
MOTOR ASSY.
PROCESS MOT CLOCK
Clock output signal for PROCESS MOTOR.
PROCESS MOT ON(L)
24VDC
On/off control signal for PROCESS MOTOR.
PROCESS MOT FAIL(H)
24VDC
Fail detection signal for PROCESS MOTOR.
Summary of Contents for AcuLaser C8500
Page 12: ......
Page 21: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Page 78: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 108: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 31 Figure 2 38 Xerographics II ...
Page 110: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 33 Figure 2 39 Development ...
Page 118: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 41 Figure 2 45 Drive ...
Page 120: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 43 Figure 2 46 Electrical ...
Page 153: ...C H A P T E R 3 DISASSEMBLY ASSEMBLY ADJUSTMENT ...
Page 269: ...C H A P T E R 4 DIAGNOSTICS ...
Page 353: ...C H A P T E R 5 TROUBLESHOOTING ...
Page 480: ...C H A P T E R 6 MAINTENANCE ...
Page 503: ...C H A P T E R 7 APPENDIX ...
Page 564: ......
Page 565: ......
Page 566: ......
Page 567: ......
Page 568: ......
Page 569: ......
Page 570: ......