Disassembly/Assembly Procedures
3-72
3.2.12.3 UPPER GUIDE ASSY (PL9.2.20) Removal
1.
Remove the EXIT TRAY ASSY. (See Section 3.2.13.1.)
2.
Pull out the FUSER ASSY.
3.
Remove the 2 screws (silver, 6mm) securing the UPPER GUIDE ASSY,
and remove the UPPER GUIDE ASSY.
Figure 3-80. UPPER GUIDE ASSY Removal