FIP-2.31 Faulty P/H MOTOR ASSY
FIP-2.31 Faulty P/H MOTOR ASSY
FIP-2.31 Faulty P/H MOTOR ASSY
FIP-2.31 Faulty P/H MOTOR ASSY
Step
Check
Treatment
Yes
No
1
*Initial setting
Use of any non-EPSON specifications, improper mounting, damage, distortion, dirt,
adherence of foreign matter?
*Main parts to check
P/H MOTOR ASSY, MAIN HARNESS ASSY, MCU PWB
Replace and remount
the concerned part(s).
Go to step 2.
2
*P/H MOTOR ASSY power supply check
Is the voltage between P/J49-2 <=> P/J49-1?
Go to step 4.
Go to step 3.
3
*LVPS power supply check
Is the voltage between J32-8 <=> J32-7 24VDC?
Replace the MAIN
HARNESS ASSY.
Go to FIP-2.2
4
*P/H MOTOR ON signal voltage check
Is the voltage between P18-11 <=> P18-8 24VDC?
Go to step 5.
Replace the MCU
PWB.
5
*P/H MOTOR SPEED signal voltage check
Is the voltage between P016B-9 <=> P016B-10 24VDC?
Go to step 6.
Replace the MCU
PWB.
6
*MAIN HARNESS ASSY continuity check
Is there a proper continuity between J50 <=> J18A?
Replace the P/H
MOTOR ASSY.
Replace the MAIN
HARNESS ASSY.
Summary of Contents for AcuLaser C8500
Page 12: ......
Page 21: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Page 78: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 108: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 31 Figure 2 38 Xerographics II ...
Page 110: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 33 Figure 2 39 Development ...
Page 118: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 41 Figure 2 45 Drive ...
Page 120: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 43 Figure 2 46 Electrical ...
Page 153: ...C H A P T E R 3 DISASSEMBLY ASSEMBLY ADJUSTMENT ...
Page 269: ...C H A P T E R 4 DIAGNOSTICS ...
Page 353: ...C H A P T E R 5 TROUBLESHOOTING ...
Page 480: ...C H A P T E R 6 MAINTENANCE ...
Page 503: ...C H A P T E R 7 APPENDIX ...
Page 564: ......
Page 565: ......
Page 566: ......
Page 567: ......
Page 568: ......
Page 569: ......
Page 570: ......