EPSON AcuLaser C8500
Revision C
Operating Principles
2-39
2.5.12 Paper Exit
EXIT-2 ROLL ASSY
Transports prints after fixing for FACE DOWN discharge on the TOP COVER
ASSY.
EXIT-3 ROLL ASSY
Transports prints after fixing for FACE DOWN discharge on the TOP COVER
ASSY.
EXIT CHUTE SWITCH
The EXIT CHUTE SWITCH is a safety switch that detects whether the EXIT
UPPER ASSY is open or closed (ON when pushed in by rib of EXIT UPPER
ASSY), and stops operation when the EXIT UPPER ASSY is open.
FUSER FAN-1
Discharges heat of the FUSER ASSY to prevent the internal temperature from
rising excessively.
EXIT CHUTE FAN
Discharges heat of the FUSER ASSY to prevent the internal temperature from
rising excessively.
TOP EXIT SENSOR
The TOP EXIT SENSOR detects passage of the print after fixing by change in
position of the actuator.
FULL STACK SENSOR
The FULL STACK SENSOR detects the specified number of prints on the TOP
COVER ASSY has been exceeded by charge in position of the actuator.
Figure 2-44. Paper Exit
Summary of Contents for AcuLaser C8500
Page 12: ......
Page 21: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Page 78: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 108: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 31 Figure 2 38 Xerographics II ...
Page 110: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 33 Figure 2 39 Development ...
Page 118: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 41 Figure 2 45 Drive ...
Page 120: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 43 Figure 2 46 Electrical ...
Page 153: ...C H A P T E R 3 DISASSEMBLY ASSEMBLY ADJUSTMENT ...
Page 269: ...C H A P T E R 4 DIAGNOSTICS ...
Page 353: ...C H A P T E R 5 TROUBLESHOOTING ...
Page 480: ...C H A P T E R 6 MAINTENANCE ...
Page 503: ...C H A P T E R 7 APPENDIX ...
Page 564: ......
Page 565: ......
Page 566: ......
Page 567: ......
Page 568: ......
Page 569: ......
Page 570: ......