EPSON AcuLaser C8500
Revision C
Troubleshooting
Level 1 FIP (Fault Isolation Procedure)
5-24
FIP-1.2 Fuser Unit Malfunction (No Fuser Unit)
FIP-1.2 Fuser Unit Malfunction (No Fuser Unit)
FIP-1.2 Fuser Unit Malfunction (No Fuser Unit)
FIP-1.2 Fuser Unit Malfunction (No Fuser Unit)
Step
Check
Treatment
Yes
No
1
*Initial setting
Use of parts of non-EPSON specifications, improper mounting, damage, distortion, dirt,
adherence of foreign matter?
*Main parts to check
FUSER ASSY, MCU PWB, FUSER HARNESS ASSY,
FUSER CONNECTOR
Replace and remount the
concerned part(s)
Go to step 2.
2
*Engine and controller division check
Can a test print (single sheet / consecutive printing, about 10 sheets each) be performed
normally with the engine alone?
Check the Printer controller (If
an error still occurs after
replacing, go to step 3.)
Go to step 3.
3
*FUSER ASSY mounting check
Is the FUSER ASSY properly mounted?
• Check by removing and reinstalling the FUSER ASSY.
With the tool:
Go to step 4.
Without the tool:
Go to step 5.
Replace the faulty part(s).
4
*FUSER ASSY detection circuit check
Is the FUSER ASSY detection circuit functioning properly?
• By using the DIAG tool, check by Digital Input Test device code “24”.
Go to step 5.
Replace the MCU PWB
5
*FUSER ASSY detection circuit power source check
Is the voltage for P19-16PIN <=> P19-15PIN 5VDC?
Go to step 6.
Replace the MCU PWB
6
*
FUSER ASSY detection signal check
Is the voltage for P/J19-18PIN <=> P/J19-7PIN as follows?
With the FUSER ASSY, the value is 0VDC.
Without the FUSER ASSY, the value is 5VDC.
Replace the MCU PWB
Go to step 7.
7
*FUSER HARNESS ASSY continuity check
Does the FUSER HARNESS ASSY
have a proper continuity between J71 <=> J78?
Go to step 9.
Replace the FUSER HARNESS
ASSY.
8
*FUSER CONNECTOR continuity check
Does the FUSER CONNECTOR have a proper continuity between P71 <=> J17?
Go to step 9.
Replace the FUSER
CONNECTOR.
Summary of Contents for AcuLaser C8500
Page 12: ......
Page 21: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Page 78: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 108: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 31 Figure 2 38 Xerographics II ...
Page 110: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 33 Figure 2 39 Development ...
Page 118: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 41 Figure 2 45 Drive ...
Page 120: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 43 Figure 2 46 Electrical ...
Page 153: ...C H A P T E R 3 DISASSEMBLY ASSEMBLY ADJUSTMENT ...
Page 269: ...C H A P T E R 4 DIAGNOSTICS ...
Page 353: ...C H A P T E R 5 TROUBLESHOOTING ...
Page 480: ...C H A P T E R 6 MAINTENANCE ...
Page 503: ...C H A P T E R 7 APPENDIX ...
Page 564: ......
Page 565: ......
Page 566: ......
Page 567: ......
Page 568: ......
Page 569: ......
Page 570: ......