EPSON AcuLaser C8500
Revision C
Chapter 4
Diagnostics
4-36
REAR_FAN
_SPEED
60
DEVE. FAN
<WARNING>
Check visually that the
rotation of the DEVE.
FAN goes to high
speed.
(During executing with
code [61], executing
this code changes the
DEVE. FAN to high
speed.)
Set DEVE. FAN SLOW-
SPEED signal to Low.
REAR_FAN
61
DEVE. FAN
<WARNING>
Check visually the
rotation of the DEVE.
FAN.
Set DEVE. FAN ON
signal to Low.
PH_MOT
_SPEED1
62
FUSER MOTOR ASSY,
P/H MOTOR ASSY
<WARNING>
<CAUTION>
Check by the change
in operational sound or
visually that the
rotation of two motors
goes to low speed (1/3
speed).
(During executing with
code [53] and [57],
executing this code
changes the FUSER
MOTOR ASSY and
the P/H MOTOR
ASSY to 1/3 speed.)
Set FUSER-P/H
MOTOR SPEED signal
to Low.
FUSER_FAN_1
63
FUSER FAN-1
<WARNING>
Check visually the
rotation (low speed) of
the FUSER FAN-1.
Set FUSER FAN-1 ON
signal to Low.
Table 4-10. Digital Output Test Device Code
Digital Output Test [DIAGSTART : [90 02 XX] , DIAGSTOP : [91 02 XX] ]
Code
Function Item
Name
(Hex)
When status data is
[High]
Check Method
FUSER_FAN_2
64
FUSER CHUTE FAN
<WARNING>
Check visually the
rotation of the FUSER
CHUTE FAN.
Set FUSER CHUTE
FAN ON signal to Low.
FUSER_FAN
_SPEED
65
FUSER FAN-1
<WARNING>
Check visually that the
rotation of the FUSER
FAN-1 goes to high
speed.
(During executing with
code [63], executing
this code changes the
FUSER FAN-1 to high
speed.)
Set FUSER FAN-1
SLOW-SPEED signal to
Low.
IBT_CLEANER_S
OL
66
CLEANER CAM
SOLENOID
<CAUTION>
Check by operational
sound that the
solenoid is operating.
Set CLEANER CAM
SOLENOID ON signal
to Low.
ADC_CLEAN
_SOL
67
ADC SENSOR ASSY
Check by operational
sound that the
solenoid is operating.
(Repeat ON/OFF with
0.12sec/1sec.)
Set ADC SOLENOID
ON signal to Low.
BTR_2ND_CL
70
BTR CAM CLUTCH
<CAUTION>
Check by operational
sound that the clutch is
operating.
Set BTR CAM CLUTCH
ON signal to Low.
ERASE_LAMP
71
ERASE LAMP ASSY
Check LED light up.
(Do it while executing
a code [54].)
Set ERASE LAMP ON
signal to Low.
ADC_LED
72
ADC SENSOR ASSY
Check the signal.
(LED of the ADC
Sensor is turned on.)
Set ADC LED ON signal
to Low.
Table 4-10. Digital Output Test Device Code
Digital Output Test [DIAGSTART : [90 02 XX] , DIAGSTOP : [91 02 XX] ]
Code
Function Item
Name
(Hex)
When status data is
[High]
Check Method
Summary of Contents for AcuLaser C8500
Page 12: ......
Page 21: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Page 78: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 108: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 31 Figure 2 38 Xerographics II ...
Page 110: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 33 Figure 2 39 Development ...
Page 118: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 41 Figure 2 45 Drive ...
Page 120: ...EPSON AcuLaser C8500 Revision C Operating Principles 2 43 Figure 2 46 Electrical ...
Page 153: ...C H A P T E R 3 DISASSEMBLY ASSEMBLY ADJUSTMENT ...
Page 269: ...C H A P T E R 4 DIAGNOSTICS ...
Page 353: ...C H A P T E R 5 TROUBLESHOOTING ...
Page 480: ...C H A P T E R 6 MAINTENANCE ...
Page 503: ...C H A P T E R 7 APPENDIX ...
Page 564: ......
Page 565: ......
Page 566: ......
Page 567: ......
Page 568: ......
Page 569: ......
Page 570: ......