988
|
Simple Network Management Protocol
www.dell.com | support.dell.com
Subscribe to Managed Object Value Updates using SNMP
By default, the Dell Force10 system displays some unsolicited SNMP messages (traps) upon certain events
and conditions. You can also configure the system to send the traps to a management station. Traps cannot
be saved on the system.
FTOS supports the following three sets of traps:
•
RFC 1157-defined traps
: coldStart, warmStart, linkDown, linkUp, authenticationFailure,
egpNeighbborLoss
•
Dell Force10 enterpriseSpecific environment traps
: fan, supply, temperature
•
Dell Force10 enterpriseSpecific protocol traps
: bgp, ecfm, stp, vrrp, xstp,
To configure the system to send SNMP notifications:
Table 48-1
lists the traps the RFC-defined SNMP traps and the command used to enable each. Note that
the coldStart and warmStart traps are enabled using a single command.
To enable a subset of Dell Force10 enterprise-specific SNMP traps, enter any of the
snmp-server enable
traps
command options in
Table 48-2
. Note that the
envmon
option enables all environment traps,
including
fan
,
supply
, and
temperature
.
Step
Task
Command
Command Mode
1
Configure the Dell Force10 system send
notifications to an SNMP server.
snmp-server host
ip-address
CONFIGURATION
2
Specify which traps the Dell Force10 system sends
to the trap receiver.
•
Enable all Dell Force10 enterpriseSpecific and
RFC-defined traps using the command
snmp-server enable traps
from
CONFIGURATION mode.
•
Enable all of the RFC-defined traps using the
command
snmp-server enable traps snmp
from CONFIGURATION mode.
snmp-server enable traps
CONFIGURATION
3
Specify the interfaces out of which FTOS sends
SNMP traps.
snmp-server trap-source
CONFIGURATION
Table 48-1. RFC 1157 Defined SNMP Traps on FTOS
Command Option
Trap
snmp authentication
SNMP_AUTH_FAIL:SNMP Authentication failed.Request with invalid community string.
snmp coldstart
SNMP_COLD_START: Agent Initialized - SNMP COLD_START.
SNMP_WARM_START: Agent Initialized - SNMP WARM_START.
snmp linkdown
PORT_LINKDN:changed interface state to down:%d
snmp linkup
PORT_LINKUP:changed interface state to up:%d
Summary of Contents for Force10 E300
Page 1: ...FTOS Configuration Guide FTOS 8 4 2 7 E Series TeraScale C Series S Series S50 S25 ...
Page 32: ...32 w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 132: ...132 802 1X w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 310: ...310 Configuration Replace and Rollback w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 330: ...330 Dynamic Host Configuration Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 402: ...402 High Availability w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 462: ...462 Interfaces w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 482: ...482 IPv4 Addressing w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 506: ...506 IPv6 Addressing w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 582: ...582 Layer 2 w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 642: ...642 Multicast Source Discovery Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 662: ...662 Multiple Spanning Tree Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 690: ...690 Object Tracking w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 754: ...754 PIM Dense Mode w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 784: ...784 PIM Source Specific Mode w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 800: ...800 Power over Ethernet w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 876: ...876 Quality of Service w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 892: ...892 Routing Information Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1006: ...1006 Simple Network Management Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1018: ...1018 SONET SDH w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1048: ...1048 Broadcast Storm Control w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1096: ...1096 Uplink Failure Detection UFD w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1098: ...1098 Upgrade Procedures w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1196: ...1196 C Series Debugging and Diagnostics w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1252: ...1252 Standards Compliance w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1262: ...1262 Index w w w d e l l c o m s u p p o r t d e l l c o m ...