High Availability |
381
Boot the chassis with dual RPMs
When you boot the system with two RPMs installed, the RPM in slot R0 is the primary RPM by default.
Both RPMs should be running the same version of FTOS. You can configure either RPM to be the primary
upon the next chassis reboot using the command
redundancy primary
from CONFIGURATION mode.
Version compatibility between RPMs
In general, the two RPMs should have the same FTOS version. However, FTOS tolerates some degree of
difference between the two versions, as described in
Table 18-1
. View the configuration loaded on each
RPM using the
show redundancy
command as shown in
Figure 18-1
.
Table 18-1. System Behavior with RPMs with Mismatched FTOS Versions
Mismatch Condition
Example
Behavior
different FTOS versions with
only first two digits matching
Primary:
7
.
4
.2.0
Standby:
7
.
4
.1.0
The link to the standby RPM is up, and FTOS block syncs only the
startup-config. The failover type is warm upgrade. FTOS displays
Message 2
.
different FTOS versions with
first two digits not matching
Primary:
7
.
6
.1.0
Standby:
7
.
5
.1.0
The link to the standby RPM is down, and the standby RPM is in a boot
loop. FTOS displays
Message 3
and a boot fail prompt.
different FTOS versions with
only first three digits matching
Primary:
7
.
4
.
2
.0
Standby:
7
.
4
.
2
.1
The link to the peer RPM is up, and FTOS performs a complete block
sync. The failover type is hot failover. FTOS displays
Message 2
.
Message 2
FTOS Version Incompatibility Error
************************************************
*
* Warning !!! Warning !!! Warning !!!
*
* ----------------------------------------------
*
* Incompatible SW Version detected !!
*
* This RPM -> 7.4.2.0
* Peer RPM -> 7.4.1.0
*
************************************************
00:00:12: %RPM0-U:CP %IRC-4-IRC_VERSION: Current RPM 7.4.2.0 Peer RPM 7.4.1.0 - Different
software version detected
00:00:12: %RPM0-U:CP %IRC-6-IRC_COMMUP: Link to peer RPM is up
00:00:14: %RPM0-U:CP %RAM-6-ELECTION_ROLE: RPM0 is transitioning to Primary RPM.
Message 3
Boot Failure on Standby RPM
System failed to boot up. Please reboot the chassis !!!
00:12:46: %RPM1-U:CP %TME-0-RPM BRINGUP FAIL: FTOS failed to bring up the system
Communication between RPMs is not up, check the software version and reboot chassis.
FTOS(standby)(bootfail)#
Summary of Contents for Force10 E300
Page 1: ...FTOS Configuration Guide FTOS 8 4 2 7 E Series TeraScale C Series S Series S50 S25 ...
Page 32: ...32 w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 132: ...132 802 1X w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 310: ...310 Configuration Replace and Rollback w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 330: ...330 Dynamic Host Configuration Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 402: ...402 High Availability w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 462: ...462 Interfaces w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 482: ...482 IPv4 Addressing w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 506: ...506 IPv6 Addressing w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 582: ...582 Layer 2 w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 642: ...642 Multicast Source Discovery Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 662: ...662 Multiple Spanning Tree Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 690: ...690 Object Tracking w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 754: ...754 PIM Dense Mode w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 784: ...784 PIM Source Specific Mode w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 800: ...800 Power over Ethernet w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 876: ...876 Quality of Service w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 892: ...892 Routing Information Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1006: ...1006 Simple Network Management Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1018: ...1018 SONET SDH w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1048: ...1048 Broadcast Storm Control w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1096: ...1096 Uplink Failure Detection UFD w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1098: ...1098 Upgrade Procedures w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1196: ...1196 C Series Debugging and Diagnostics w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1252: ...1252 Standards Compliance w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1262: ...1262 Index w w w d e l l c o m s u p p o r t d e l l c o m ...