S-Series Debugging and Diagnostics |
1225
Figure 62-5. Viewing the Results of Offline Diagnostics on a Standalone Unit
Trace logs
In addition to the syslog buffer, FTOS buffers trace messages which are continuously written by various
FTOS software tasks to report hardware and software events and status information. Each trace message
provides the date, time, and name of the FTOS process. All messages are stored in a ring buffer and can be
saved to a file either manually or automatically upon failover.
FTOS#show file flash://TestReport-SU-0.txt
**********************************S-Series Diagnostics********************
Stack Unit Board Serial Number : DL267160098
CPU Version : MPC8541, Version: 1.1
PLD Version : 5
Diag image based on build : E_MAIN4.7.7.206
Stack Unit Board Voltage levels - 3.300000 V, 2.500000 V, 1.800000 V, 1.250000 V, 1.200000
V, 2.000000 V
Stack Unit Board temperature : 26 Degree C
Stack Unit Number : 0
****************************Stack Unit EEPROM INFO*******************************
********MFG INFO*******************
Data in Chassis Eeprom Mfg Info is listed as...
Vendor Id: 07
Country Code: 01
Date Code: 12172007
Serial Number: DL267160098
Part Number: 7590003600
Product Revision: B
Product Order Number: ${
**************************** LEVEL 0 DIAGNOSTICS**************************
Test 0 - CPLD Presence Test ......................................... PASS
Hardware PCB Revision is - Revision B
Test 1 - CPLD Hardware PCB Revision Test ............................ PASS
Test 2.000 - CPLD Fan-0 Presence Test ............................... PASS
Test 2.001 - CPLD Fan-1 Presence Test ............................... PASS
Test 2.002 - CPLD Fan-2 Presence Test ............................... PASS
Test 2.003 - CPLD Fan-3 Presence Test ............................... PASS
Test 2.004 - CPLD Fan-4 Presence Test ............................... PASS
Test 2.005 - CPLD Fan-5 Presence Test ............................... PASS
Test 3.000 - CPLD Power Bay-0 Presence Test ......................... PASS
Test 3.001 - CPLD Power Bay-1 Presence Test ......................... NOT PRESENT
Test 4 - SDRAM Access Test .......................................... PASS
Test 5 - CPU Access Test ............................................ PASS
Test 6 - I2C Temp Access Test CPU Board ............................. PASS
Test 7 - I2C Temp Access Test Main Board ............................ PASS
Test 8 - RTC Access Test ............................................ PASS
--More--
Summary of Contents for Force10 E300
Page 1: ...FTOS Configuration Guide FTOS 8 4 2 7 E Series TeraScale C Series S Series S50 S25 ...
Page 32: ...32 w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 132: ...132 802 1X w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 310: ...310 Configuration Replace and Rollback w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 330: ...330 Dynamic Host Configuration Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 402: ...402 High Availability w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 462: ...462 Interfaces w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 482: ...482 IPv4 Addressing w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 506: ...506 IPv6 Addressing w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 582: ...582 Layer 2 w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 642: ...642 Multicast Source Discovery Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 662: ...662 Multiple Spanning Tree Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 690: ...690 Object Tracking w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 754: ...754 PIM Dense Mode w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 784: ...784 PIM Source Specific Mode w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 800: ...800 Power over Ethernet w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 876: ...876 Quality of Service w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 892: ...892 Routing Information Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1006: ...1006 Simple Network Management Protocol w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1018: ...1018 SONET SDH w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1048: ...1048 Broadcast Storm Control w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1096: ...1096 Uplink Failure Detection UFD w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1098: ...1098 Upgrade Procedures w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1196: ...1196 C Series Debugging and Diagnostics w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1252: ...1252 Standards Compliance w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 1262: ...1262 Index w w w d e l l c o m s u p p o r t d e l l c o m ...