Troubleshooting by Error Code
SiUS342303E
343
Part 6 Service Diagnosis
Reference
CHECK 4
Refer to page 376.
The
inverter PCB has
damage.
The
system enters
standby mode before the
outdoor fan starts
rotating.
The
system enters
standby mode before
completing the startup
operation of the
compressor.
The error
U2
recurs.
NO
NO
YES
YES
NO
YES
NO
YES
Replace the inverter PCB.
Check for wirings.
Turn ON the power supply,
and then press the ON button.
Replace the inverter PCB.
If the inverter PCB gets
severely damaged, the
compressor and the fan
motor (M1F, M2F) may
have been damaged.
Replace the inverter PCB.
If the inverter PCB gets
severely damaged, check
for the compressor.
Continue operation.
The error could have
resulted from causes such
as instantaneous power
failure.
A
Is the power
transistor normal?
YES
NO
Replace the inverter PCB.
Connect and disconnect the
connectors connecting the
main PCB to inverter PCB.
CHECK 4
The insulation
resistance of the fan
motor is not more than
1 M
.
NO
YES
Replace the fan motor
(M1F, M2F).
If the motor gets severely
damaged, the inverter
PCB should also be
replaced.
Summary of Contents for VRV EMERION RXYQ-AATJA
Page 1: ...Service Manual Heat Pump 60 Hz RXYQ AATJA 208 230 V RXYQ AAYDA 460 V SiUS342303E...
Page 410: ...Wiring Diagrams SiUS342303E 403 Part 7 Appendix FXEQ07 09 12 15 18 24PVJU 3D098557A...
Page 411: ...SiUS342303E Wiring Diagrams Part 7 Appendix 404 FXDQ07 09 12 18 24MVJU C 3D050501C...
Page 416: ...Wiring Diagrams SiUS342303E 409 Part 7 Appendix FXHQ12 24 36MVJU 3D048116C...
Page 417: ...SiUS342303E Wiring Diagrams Part 7 Appendix 410 FXAQ07 09 12 18 24PVJU 3D075354F...
Page 424: ...Wiring Diagrams SiUS342303E 417 Part 7 Appendix VAM1200GVJU 3D073270D...