Model Names
SiUS342303E
11
Part 1 General Information
Note(s)
1.2 Indoor
Unit
VJ: 1 phase, 208/230 V, 60 Hz
SBL: 1 phase, 115 V, 60 Hz
U: Standard symbol
1. Low-temperature hydrobox index for calculating system capacity shows in below table.
Please use the index at system connection ratio calculation.
1.3 Air Treatment Equipment
VJ: 1 phase, 208/230 V, 60 Hz
U: Standard symbol
Capacity range (ton)
0.5
0.6
0.8
1
1.25
1.5
2
2.5
3
3.5
4
4.5
5
6
8
Power
supply,
Standard
Capacity index
5.8
7.5
9.5
12
15
18
20
24
30
36
42
48
54
60
72
96
Ceiling mounted
cassette
(Round flow with
sensing) type
FXFQ
—
07T
09T
12T
15T
18T
—
24T
30T
36T
—
48T
—
—
—
—
VJU*
VISTA
TM
2'×2'
cassette type
FXZQ
05TB
07TB
09TB
12TB
15TB
18TB
—
—
—
—
—
—
—
—
—
—
4-way blow ceiling
suspended type
FXUQ
—
—
—
—
—
—
18PA
24PA
30PA
36PA
—
—
—
—
—
—
One way blow
cassette type
FXEQ
—
07P
09P
12P
15P
18P
—
24P
—
—
—
—
—
—
—
—
Slim ceiling mounted
duct type
FXDQ
—
07M
09M
12M
—
18M
—
24M
—
—
—
—
—
—
—
—
MSP concealed
ducted type
FXSQ
05TB
07TB
09TB
12TB
15TB
18TB
—
24TB
30TB
36TB
—
48TB
54TB
—
—
—
Ceiling mounted
duct type (Middle
and high static
pressure)
FXMQ
—
07PB
09PB
12PB 15PB
18PB
—
24PB
30PB
36PB
—
48PB
54PB
—
—
—
Ceiling mounted
duct type (High
static pressure)
FXMQ
—
—
—
—
15TB
18TB
—
24TB
30TB
36TB
—
48TB
54TB
—
—
—
Ceiling mounted
duct type
FXMQ
—
—
—
—
—
—
—
—
—
—
—
—
—
—
72M
96M
Ceiling suspended
type
FXHQ
—
—
—
12M
—
—
—
24M
—
36M
—
—
—
—
—
—
Wall mounted type
FXAQ
—
07P
09P
12P
—
18P
—
24P
—
—
—
—
—
—
—
—
Floor standing type
FXLQ
—
07M
09M
12M
—
18M
—
24M
—
—
—
—
—
—
—
—
Concealed floor
standing type
FXNQ
—
07M
09M
12M
—
18M
—
24M
—
—
—
—
—
—
—
—
Air handling unit
FXTQ
—
—
09TA
12TA
—
18TA
—
24TA
30TA
36TA
42TA
48TA
54TA
60TA
—
—
VJUA*
—
—
09TA
12TA
—
18TA
—
24TA
30TA
36TA
42TA
48TA
54TA
60TA
—
—
VJUD*
Cased Coil Unit
CXTQ
—
—
—
—
—
—
—
24TA
—
36TA
—
48TA
—
60TA
—
—
SBLU*
Low-temperature
hydrobox (
1)
HXY
—
—
—
—
—
—
—
—
—
—
—
48TA
—
—
—
—
VJU*
Target
Δ
T difference [°F]
5.4
7.2
9
10.8
12.6
≤
Index
25.6
34.2
42.7
48
48
Outdoor-Air Processing Unit
Series
Model name
Power supply,
Standard
FXMQ
48MF
72MF
96MF
VJU*
Energy Recovery Ventilator (VAM series)
Series
Model name
Power supply,
Standard
VAM
300G
470G
600G
1200G
VJU*
Summary of Contents for VRV EMERION RXYQ-AATJA
Page 1: ...Service Manual Heat Pump 60 Hz RXYQ AATJA 208 230 V RXYQ AAYDA 460 V SiUS342303E...
Page 410: ...Wiring Diagrams SiUS342303E 403 Part 7 Appendix FXEQ07 09 12 15 18 24PVJU 3D098557A...
Page 411: ...SiUS342303E Wiring Diagrams Part 7 Appendix 404 FXDQ07 09 12 18 24MVJU C 3D050501C...
Page 416: ...Wiring Diagrams SiUS342303E 409 Part 7 Appendix FXHQ12 24 36MVJU 3D048116C...
Page 417: ...SiUS342303E Wiring Diagrams Part 7 Appendix 410 FXAQ07 09 12 18 24PVJU 3D075354F...
Page 424: ...Wiring Diagrams SiUS342303E 417 Part 7 Appendix VAM1200GVJU 3D073270D...