NOTICE TO INSTALLER:  Instructions must remain with installation.

MODELS 580 & 585

BATTERY BACKUP PEDESTAL SUMP PUMP

P/N 01

1952

PREINSTALLATION CHECKLIST

© Copyright 2009 Zoeller Co. All rights reserved.

Product information presented 

here re fl ects con di tions at time 

of  publication. Consult factory 

re gard ing  dis crep an cies  or 

in con sis ten cies.

  P.O. BOX 16347 • Louisville, KY  40256-0347

  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

1.  Inspect your pump. Occasionally, products are dam aged during shipment. If the unit or any of the parts are dam aged, contact your dealer 

before us ing.

2.  Read all the installation instructions regarding in stall ing and start up. Retain for future ref er ence.

1.  Make sure there is a properly ground ed 115V re cep tacle avail-

 able. Do not use primary pump cir cuit. The location must be within 

6' of the control box and battery. The power supply for your DC 

control system plugs directly into the 115V outlet. DO NOT USE 

AN  EX TEN SION  CORD.

2.  Make sure the 115V electrical supply circuit is equipped 

with fuses or circuit breakers of prop er capacity.

3.  DC emergency pumps are de signed for han dling clear water. Do 

not use in septic tanks to pump ef fl u ent or sew age pits to pump 

sewage.

4.  Repair and service of your DC backup sys tem should be per formed 

by an authorized service station.

5.  The installation of DC automatic back up pumps re quires the use 

of a variable level fl oat switch for operation. It is the responsibility 

of the installing party, to ensure that the teth ered fl oat switch will 

not hang up on the pump ap pa ra tus or pit pe cu li ari ties and is 

secured so the pump will turn “on” and “off”. It is recommended 

that the pit be 18" in diameter or larger to ac com mo date both a 

pri ma ry and a DC backup pump. 

SEE BELOW FOR LIST OF WARNINGS

1.  Testing for Ground. As a safe ty mea sure each elec tri cal outlet 

should be checked for ground using an Underwriters Laboratory 

list ed cir cuit ana lyzer, which will indicate if the power, neu tral and 

ground wires are correctly con nected to your out let. If they are 

not, call a qualifi ed licensed electrician.

2.  For your pro tec tion always dis con nect the pow er supply from 

its power source before handling the com po nents of your DC 

back up pump or the pri ma ry pump.

3.  Installation and checking of elec tri cal cir cuits and hard ware should 

be per formed by a qualifi ed, li censed electrician. 

4.  All elec tri cal and safety codes must be fol lowed in ad di tion to the 

National Electrical Code and all applicable local codes. 

5.  

It is the owner’s responsibility to check the bat tery 

and bat tery connection at least once a month. Bat-

 ter ies con tain acid and cau tion must be taken when 

han dling.

6.  Risk of electric shock - These pumps have not been investigated 

for use in swimming pool areas.

7.  According to the state of California (Prop 65), this product contains 

chemicals known to the state of California to cause cancer and 

birth defects or other reproductive harm.

SEE BELOW FOR LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

Summary of Contents for AQUANOT 585

Page 1: ...DC automatic backup pumps requires the use of a variable level float switch for operation It is the responsibility of the installing party to ensure that the tethered float switch will not hang up on...

Page 2: ...LORINCIDENTALDAMAGESORBREACH OF EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARR...

Page 3: ...discharge pipe smaller than the recommended pump discharge sizes 6 DO test pump immediately after installation to be sure that the system is working properly 7 DO review all applicable local and nati...

Page 4: ...e the pump from the pit and adjust the float stops as necessary Tighten all screws Note If a brick or similar material has been used to raise the pump in the pit it will be necessary to account for th...

Page 5: ...Do not put the battery monitor on top of the battery Figure 5 1 STEP 6 Testing of Pump Operation 6 1 Unplug the primary pump so that it does not start 6 2 Fill pit with water until the Aquanot starts...

Page 6: ...Aquanot Charger Model 585 Only All Aquanot pump systems are equipped with an alarm which sounds when the pump is activated The alarm will automatically silence when the pumping cycle is completed Act...

Page 7: ...011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 10 Adapter Drive 1 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 11 Shaft 1 01...

Page 8: ...as depleted below 5V due to prolonged operation without AC power Call for service or replace battery F RED LIGHT FLASHING MODEL 585 The charger fan may be defective Have a qualified electrician inspec...

Reviews: