402-00005-00
Introduction
1–2
Rev 02; February 8, 2002
1.2 PCVisionplus SPECIFICATIONS
•
The PCVisionplus video connectors are pin-compatible with the previous PCVision PCI-bus frame grabber and
camera cables. New cables support new camera features.
•
A hardware jumper selects the power-up state of the OPTO-22 compatible I/O port. All parallel port outputs have
an initial setting of either all 0 or all 1 based on the jumper setting. This feature adds flexibility when interfacing
with LEDs and module racks. Refer to Figure 1–4.
•
All addresses are assigned by the PCI-bus host computer. All configurable hardware characteristics are software
controlled.
1.2.1 PCVisionplus Video Inputs
•
Standard RS170 or CCIR (monochrome).
•
Progressive scan and non-standard (variable scan) up to 53 MHz. VCR and VTR are not supported.
•
Two AC-coupled video inputs, terminated into 75 ohms.
•
DC Restoration – automatic clamp pulse from stripped sync or programmable clamp pulse; programmable clamp
voltage 0 to 2.5 Volts.
•
Low-Pass Filters – 6.5 MHz and 12.5 MHz.
•
Input gain – 2.1 (fixed)
•
Programmable ADC positive and negative voltage references from 13-bit DACs, range 0 to 3.3 Volts.
•
12-bit 53 MHz ADC
1.2.2 PCVisionplus Timing Inputs (Standard Video)
•
Composite analog sync on video from CAM0 or CAM1.
•
Separate Horizontal and Vertical digital sync; negative voltages not allowed.
•
Programmable Sync Stripper line rate: 15 KHz to 66.5 KHz, supports non-standard line rates in PLL mode.
VSYNC, HSYNC
Vi
0 to 5 V
Input voltage range
Vh min
2 V
Minimum high–level voltage
Vl max
0.8 V
Maximum low–level voltage
R
10 kohms
PCVisionplus pull-up resistors
•
Three miscellaneous camera control inputs.
1.2.3 Variable Scan Timing Inputs
•
Area scan cameras up to 4K pixels by 4K lines. Line scan is not supported.
•
Variable Scan inputs LEN, FEN, CLK digital timing from CAM0 or CAM1, negative voltages not allowed.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com