Chapter 9
9-5
9.4.2 Detecting an Error
0006-6013
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N /
/ iR4570N / iR2230 / / / iR3530 /
As part of its protective mechanism, the machine checks for the following er-
ror conditions:
T-9-3
9.5 Parts Replacement Procedure
9.5.1 Fixing Unit
9.5.1.1 Removing the Right Cover (rear)
0007-7874
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N /
/ iR4570N / iR2230 / / / iR3530 /
1) Open the pedestal right door [1]. (if equipped with a 2-Cassette Pedestal-
Y2)
2) Open the right lower door [2].
3) Remove the 5 screws [3], and detach the right cover (rear) [4].
F-9-6
9.5.1.2 Removing the Right Door
0007-7879
iR3570 / iR4570 / / iR3570N / / iR4570N / iR2230 / / / iR3530 /
1) Open the right door.
F-9-7
2) Remove the screw [1], and detach the fixing plate [2].
F-9-8
3) Remove the joint shaft [1], and free the extension delivery unit [2] from
the right door.
Error code
Detail code Symptom
Description
E000
0000
The fixing temperature fails
to increase.
In the course of start-up control, the thermistor reading
is less than 30 deg C 1 sec after the start of power supply
or is less than 70 deg C 2 sec after the start of power
supply; the machine will identify an error condition if
any of the foregoing continues for 200 msec or more.
E001
0000
The thermistor detects
overheating.
The thermistor detects 235 deg C for 200 msec or more
continuously.
0001
A hardware circuit detects
overheating.
A hardware circuit detects overheating in relation to the
thermistor (main or sub).
0002
The sub thermistor detects
overheating.
The thermistor detects 295 deg C or more for 200 msec
or more continuously.
E002
0000
The fixing temperature fails
to reach a specific level.
In the course of start-up control, the thermistor detects a
temperature lower then 115 deg C for 200 msec
continuously after it has detected 100 deg C; the
thermistor detects a temperature less than 150 deg C for
200 msec or more continuously after it has detected 140
deg C; or, the thermistor detects a temperature lower
than 165 deg C for 20 msec or more continuously 1 sec
after it has detected 160 deg C.
E003
0000
The fixing temperature has
dropped to an abnormally
low level.
In the course of normal temperature control, the
thermistor detects a temperature lower than 140 deg C
for 20 msec or more continuously.
E007
0000
The fixing film rotates in an
abnormal way.
The reading of the main thermistor is in excess of 100
deg C with the fixing motor in a locked state and, in
addition, the machine fails to detect the marker signal
for 6 sec.
E014
0000
The machine detects a
fixing motor error.
During operation, the machine detects an overload
condition continuously for 3 sec or more.
[1]
[2]
[3]
[3]
[3]
[4]
Summary of Contents for iR3570 Series
Page 1: ...Jan 17 2007 Service Manual iR4570 3570 2870 2270 Series...
Page 2: ......
Page 6: ......
Page 27: ...Chapter 1 Introduction...
Page 28: ......
Page 70: ......
Page 71: ...Chapter 2 Installation...
Page 72: ......
Page 146: ......
Page 147: ...Chapter 3 Basic Operation...
Page 148: ......
Page 150: ......
Page 154: ......
Page 155: ...Chapter 4 Main Controller...
Page 156: ......
Page 187: ...Chapter 5 Original Exposure System...
Page 188: ......
Page 217: ...Chapter 5 5 27 F 5 91...
Page 218: ......
Page 219: ...Chapter 6 Laser Exposure...
Page 220: ......
Page 222: ......
Page 230: ......
Page 231: ...Chapter 7 Image Formation...
Page 232: ......
Page 236: ......
Page 280: ......
Page 281: ...Chapter 8 Pickup Feeding System...
Page 282: ......
Page 388: ......
Page 389: ...Chapter 9 Fixing System...
Page 390: ......
Page 419: ...Chapter 9 9 27 F 9 148...
Page 420: ......
Page 421: ...Chapter 10 External and Controls...
Page 422: ......
Page 426: ......
Page 437: ...Chapter 10 10 11 F 10 12 2 Remove the check mark from SNMP Status Enabled...
Page 438: ...Chapter 10 10 12 F 10 13...
Page 440: ...Chapter 10 10 14 F 10 15...
Page 475: ...Chapter 11 MEAP...
Page 476: ......
Page 478: ......
Page 481: ...Chapter 12 Maintenance and Inspection...
Page 482: ......
Page 484: ......
Page 509: ...Chapter 13 Standards and Adjustments...
Page 510: ......
Page 512: ......
Page 521: ...Chapter 14 Correcting Faulty Images...
Page 522: ......
Page 528: ......
Page 537: ...Chapter 14 14 9 43mm s b Z x i j B iR4570_395 s u A B FM2 0287...
Page 538: ...Chapter 14 14 10...
Page 539: ...Chapter 14 14 11...
Page 585: ...Chapter 15 Self Diagnosis...
Page 586: ......
Page 588: ......
Page 623: ...Chapter 16 Service Mode...
Page 624: ......
Page 626: ......
Page 679: ...Chapter 17 Upgrading...
Page 680: ......
Page 682: ......
Page 693: ...Chapter 17 17 11 F 17 18 2 Click Start F 17 19 3 When the session has ended click OK...
Page 698: ...Chapter 17 17 16 F 17 28 2 Click Start F 17 29 3 When the session has ended click OK...
Page 710: ...Chapter 17 17 28 F 17 51 3 Click Start F 17 52 4 Click Save...
Page 712: ...Chapter 17 17 30 F 17 55 2 Select the data to download F 17 56 3 Click Start...
Page 714: ......
Page 715: ...Chapter 18 Service Tools...
Page 716: ......
Page 718: ......
Page 720: ......
Page 721: ...Jan 17 2007...
Page 722: ......