Chapter 15
15-12
- HD-CLEAR
When you have executed HD-CLEAR, all contents of the partition in question (files, sub directories) will be lost.
The actual formatting will take place when the machine is started up after it has been turned off upon execution of HD-CLEAN.
At this time, the Startup screen shows a progress bar, its edge reaching the end in about 5 min. Be sure not to turn off the power while the progress bar is moving.
This function (i.e., mode item) cannot be used for BOOTDEV and DOSDEV4; to re-format any of these 2 partitions, you will have to use the SST.
Keep in mind that formatting of the HDD in service mode will necessarily be full formatting.
- HD-CHECK
If the power is cut while data is being written to the HDD, the occurrence of a write-suspended sector is a possibility. When HD-CHECK is run on such a sector,
repairs will be made, but all data in the sector will be lost. A write-suspended sector may be repaired only by HDD-CHECK (0); if not TYPE-TYPE=0, the task
will be limited to an FS level check.
If the write-suspended sector happens to be a critical sector that holds a control area, there is no way of repairing it; you will have to execute HDD formatting.
- Replacing the HDD
1. Turn off the main switch.
2. Connect the new HDD.
3. Start up the machine in safe mode.
4. Connect the SST, and execute full formatting.
5. Using the SST, download the system software (System, Language, RUI).
6. Turn off and then back on the power. (It may take about 5 min for the machine to start up).
15.2.3 Error Code DetailsÅitest for A4 sizeÅj
0009-7180
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 / / / / /
T-15-7
Code
Cause
Remedy
E000
The temperature of the fixing assembly is abnormally high.
0001 While startup control is under way, the reading of the main thermistor is less than
30 deg C continuously for 200 msec or more 1 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than
70 deg C continuously for 200 msec or more 2 sec after the start of power supply.
While startup control is under way, the reading of the main thermistor is less than
120 deg C continuously for 200 msec 6 sec after the start of power supply.
The startup control does not end 30 sec after the start of power supply.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor.
Replace the DC controller PCB.
E001
The temperature of the fixing assembly is abnormally high.
0000 The reading of the main thermistor is 250 deg C or more continuously for 200
msec.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor.
Replace the DC controller PCB.
0001 The hardware circuit detects overheating of the main or sub thermistor for 200
msec.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR. Replace the DC controller
PCB.
0002 The reading of the sub thermistor is 295 deg C or more continuously for 200 msec. Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR. Replace the sub thermistor.
Replace the DC controller PCB.
E002
The rise in temperature of the fixing assembly is faulty.
0000 While startup control is under way, the reading of the main thermistor is less than
115 deg C continuously for 400 msec 1.3 sec after it has indicated 100 deg C.
While startup control is under way, the reading of the main thermistor is less than
150 deg C continuously for 400 msec 1.3 sec after it has indicated 140 deg C.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor.
Replace the DC controller PCB.
E003
The fixing temperature is too low after a standby state.
0000 While regular temperature control is under way, the reading of the main
thermistor is less than 140 deg C continuously for 400 msec or more.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor.
Replace the DC controller PCB.
E007
The rotation of the fixing film is faulty.
0000 While the fixing motor is rotating, the marker signal is not detected for 6 sec with
the reading of the main thermistor indicating 100 deg C or more.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor.
Replace the DC controller PCB.
E010
The rotation of the main motor is faulty.
0001 Detection is executed every 100 msec after the start of motor rotation; however,
the drive detection signal is absent for 2 sec.
Replace the main motor. Replace the DC controller PCB.
0002 During motor rotation, detection is executed every 100 msec; however, the drive
signal is absent 5 times in sequence.
Replace the main motor. Replace the DC controller PCB.
E014
The rotation of the fixing motor is faulty.
0001 Detection is executed every 100 msec after the start of motor rotation; however,
the drive detection signal is absent for 2 sec.
Replace the fixing motor. Replace the DC controller PCB.
0002 During motor rotation, detection is executed every 100 msec; however, the drive
signal is absent 5 times in sequence.
Replace the fixing motor. Replace the DC controller PCB.
E019
The waste toner case is full, or the waste toner case full sensor is faulty.
0000 When the waste toner case is identified as being full for 2000 prints continuously,
an alert is issued; thereafter, the case is identified as being full continuously for
100 prints.
Replace the waste toner sensor. Replace the DC controller PCB.
E020
The path between the sub hopper and the developing assembly is clogged with toner.
0000 The developing assembly toner sensor detects the absence of toner, while the sub
hopper toner sensor detects the presence of toner. With the developing clutch
turned on, the hopper feedscrew motor is rotated for 1 sec intermittently 194
times; still, the developing assembly toner sensor does not detect the presence of
toner.
Replace the developing assembly toner sensor. Replace the sub
hopper toner sensor. Replace the DC control PCB.
E024
The developing assembly connector is disconnected.
0000 The connection detection signal is absent continuously for 100 msec.
Replace the developing assembly toner sensor. Connect the
connector. Replace the DC controller PCB.
Summary of Contents for iR3570 Series
Page 1: ...Jan 17 2007 Service Manual iR4570 3570 2870 2270 Series...
Page 2: ......
Page 6: ......
Page 27: ...Chapter 1 Introduction...
Page 28: ......
Page 70: ......
Page 71: ...Chapter 2 Installation...
Page 72: ......
Page 146: ......
Page 147: ...Chapter 3 Basic Operation...
Page 148: ......
Page 150: ......
Page 154: ......
Page 155: ...Chapter 4 Main Controller...
Page 156: ......
Page 187: ...Chapter 5 Original Exposure System...
Page 188: ......
Page 217: ...Chapter 5 5 27 F 5 91...
Page 218: ......
Page 219: ...Chapter 6 Laser Exposure...
Page 220: ......
Page 222: ......
Page 230: ......
Page 231: ...Chapter 7 Image Formation...
Page 232: ......
Page 236: ......
Page 280: ......
Page 281: ...Chapter 8 Pickup Feeding System...
Page 282: ......
Page 388: ......
Page 389: ...Chapter 9 Fixing System...
Page 390: ......
Page 419: ...Chapter 9 9 27 F 9 148...
Page 420: ......
Page 421: ...Chapter 10 External and Controls...
Page 422: ......
Page 426: ......
Page 437: ...Chapter 10 10 11 F 10 12 2 Remove the check mark from SNMP Status Enabled...
Page 438: ...Chapter 10 10 12 F 10 13...
Page 440: ...Chapter 10 10 14 F 10 15...
Page 475: ...Chapter 11 MEAP...
Page 476: ......
Page 478: ......
Page 481: ...Chapter 12 Maintenance and Inspection...
Page 482: ......
Page 484: ......
Page 509: ...Chapter 13 Standards and Adjustments...
Page 510: ......
Page 512: ......
Page 521: ...Chapter 14 Correcting Faulty Images...
Page 522: ......
Page 528: ......
Page 537: ...Chapter 14 14 9 43mm s b Z x i j B iR4570_395 s u A B FM2 0287...
Page 538: ...Chapter 14 14 10...
Page 539: ...Chapter 14 14 11...
Page 585: ...Chapter 15 Self Diagnosis...
Page 586: ......
Page 588: ......
Page 623: ...Chapter 16 Service Mode...
Page 624: ......
Page 626: ......
Page 679: ...Chapter 17 Upgrading...
Page 680: ......
Page 682: ......
Page 693: ...Chapter 17 17 11 F 17 18 2 Click Start F 17 19 3 When the session has ended click OK...
Page 698: ...Chapter 17 17 16 F 17 28 2 Click Start F 17 29 3 When the session has ended click OK...
Page 710: ...Chapter 17 17 28 F 17 51 3 Click Start F 17 52 4 Click Save...
Page 712: ...Chapter 17 17 30 F 17 55 2 Select the data to download F 17 56 3 Click Start...
Page 714: ......
Page 715: ...Chapter 18 Service Tools...
Page 716: ......
Page 718: ......
Page 720: ......
Page 721: ...Jan 17 2007...
Page 722: ......