Field Remedy
When a faulty image like the above has occurred, replace the laser scanner assembly with a new one.
Note: After replacing the laser scanner assembly, never fail to input the "Delay value" on the label attached to the old laser scanner assembly into the following
service mode:
[Service mode > COPIER > ADJUST > LASER > LA-DELAY]
FM2-0276 Laser Scanner Assembly (for iR2270/2870 series)
FM2-0334 Laser Scanner Assembly (for iR3570/4570 series)
14.2.1.7.2 DADF-N1: Image stretch or shrinkage (in sub scanning direction) occurs in stream reading upon installation
0010-6550
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 / / / / /
[ Case in the field ]
Description
In the field, image stretch or shrinkage occurred depending on the types of paper used. This was because the service mode item "LA-SPEED" (adjustment of
original feeding speed in stream reading) was not executed upon installation.
Field Remedy
When the symptom has occurred, follow the procedure below.
1. Place the Test Chart in the DADF-N1 and make a copy. Refer to the output as "Copy A."
2. Compare the Test Chart and Copy A in terms of the length of the image in feed direction.
3. In service mode [FEEDER > ADJUST > LA-SPEED], adjust the setting as follows. (Unit of adjustments: 0.1%)
- As a result of the comparison in Step2, if the image of Copy A is longer, increase the setting to shrink the image.
- As a result of the comparison in Step2, if the image of Copy A is shorter, decrease the setting to stretch the image.
14.2.1.7.3 Output image is scaled down in original feed direction because CIS read position is shifted: After replacing paper pick-up
assembly for DADF-N1
0011-6435
iR2270 / iR2870 / iR3570 / iR4570 / / iR2270N / / iR2870N / / iR3570N / / iR4570N / iR2230 / / / iR3530 / / / / / / /
[ Case in the field ]
Description
In the field, the CIS read position was shifted after replacement of the paper pick-up assembly for the DADF-N1, the output image was scaled down in the
original feed direction. When the symptom has occurred, perform the following field remedy.
Field Remedy
1. CIS read position adjustment
Service mode > COPIER > Function > INSTALL > STRD-POS > OK
2. Magnification adjustment
In Service mode [FEEDER > Adjust], decrease the setting value for [LA-SPEED]. (Adjustable range: -30 to 30).
Note: Increasing this setting value will increase the original feed speed, thus scaling down the output image. Conversely, decreasing the value will decrease
the original feed speed, thus scaling up the output image.
Summary of Contents for iR3570 Series
Page 1: ...Jan 17 2007 Service Manual iR4570 3570 2870 2270 Series...
Page 2: ......
Page 6: ......
Page 27: ...Chapter 1 Introduction...
Page 28: ......
Page 70: ......
Page 71: ...Chapter 2 Installation...
Page 72: ......
Page 146: ......
Page 147: ...Chapter 3 Basic Operation...
Page 148: ......
Page 150: ......
Page 154: ......
Page 155: ...Chapter 4 Main Controller...
Page 156: ......
Page 187: ...Chapter 5 Original Exposure System...
Page 188: ......
Page 217: ...Chapter 5 5 27 F 5 91...
Page 218: ......
Page 219: ...Chapter 6 Laser Exposure...
Page 220: ......
Page 222: ......
Page 230: ......
Page 231: ...Chapter 7 Image Formation...
Page 232: ......
Page 236: ......
Page 280: ......
Page 281: ...Chapter 8 Pickup Feeding System...
Page 282: ......
Page 388: ......
Page 389: ...Chapter 9 Fixing System...
Page 390: ......
Page 419: ...Chapter 9 9 27 F 9 148...
Page 420: ......
Page 421: ...Chapter 10 External and Controls...
Page 422: ......
Page 426: ......
Page 437: ...Chapter 10 10 11 F 10 12 2 Remove the check mark from SNMP Status Enabled...
Page 438: ...Chapter 10 10 12 F 10 13...
Page 440: ...Chapter 10 10 14 F 10 15...
Page 475: ...Chapter 11 MEAP...
Page 476: ......
Page 478: ......
Page 481: ...Chapter 12 Maintenance and Inspection...
Page 482: ......
Page 484: ......
Page 509: ...Chapter 13 Standards and Adjustments...
Page 510: ......
Page 512: ......
Page 521: ...Chapter 14 Correcting Faulty Images...
Page 522: ......
Page 528: ......
Page 537: ...Chapter 14 14 9 43mm s b Z x i j B iR4570_395 s u A B FM2 0287...
Page 538: ...Chapter 14 14 10...
Page 539: ...Chapter 14 14 11...
Page 585: ...Chapter 15 Self Diagnosis...
Page 586: ......
Page 588: ......
Page 623: ...Chapter 16 Service Mode...
Page 624: ......
Page 626: ......
Page 679: ...Chapter 17 Upgrading...
Page 680: ......
Page 682: ......
Page 693: ...Chapter 17 17 11 F 17 18 2 Click Start F 17 19 3 When the session has ended click OK...
Page 698: ...Chapter 17 17 16 F 17 28 2 Click Start F 17 29 3 When the session has ended click OK...
Page 710: ...Chapter 17 17 28 F 17 51 3 Click Start F 17 52 4 Click Save...
Page 712: ...Chapter 17 17 30 F 17 55 2 Select the data to download F 17 56 3 Click Start...
Page 714: ......
Page 715: ...Chapter 18 Service Tools...
Page 716: ......
Page 718: ......
Page 720: ......
Page 721: ...Jan 17 2007...
Page 722: ......