Chapter 16
16-32
FIX-TEMP
Switching the plain paper down sequence table
1
<Setting range>
0: OFF (Default)
1: Prioritize productivity. Set the control temperature at -20 deg C across the board.
2: Set the control temperature at -10 deg C across the board.
3: It is -20Åé only in case of 21Åé or more in room temperature as for the control
temperature.
4: It is -10Åé only in case of 21Åé or more in room temperature as for the control
temperature.
5: Set the control temperature at +6 deg C across the board.
6: Set the control temperature at +10 deg C across the board.
7: Set the control temperature at +15 deg C across the board.
(For DCON Ver.15 or later)
<Additional information>
This can be set with TEMP-COM or TEMPCON2.
Example)
When FIX-TEMP is set to -6 deg C and TEMP-COM is set to -6 deg C , the control
temperature is offset by -12 deg C .
TRANS-SW Switching transfer high-voltage control from constant current control to constant
voltage control
1
<Setting range>
0: No switching [Default], 1: Constant voltage mode 1, 2: Constant voltage mode 2
TEMP-CON Switching the thick paper fixing temperature mode
1
<Setting range>
0: OFF (Default)
1: Prioritize productivity. Set the control temperature at -10 deg C across the board.
2: Set the control temperature at -6 deg C across the board.
3: Set the control temperature at -3 deg C across the board.
4: Prioritize fixing performance. Set the control temperature at +3 deg C across the
board.
5: Set the control temperature at +6 deg C across the board.
6: Set the control temperature at +10 deg C across the board.
7: Set the control temperature at +15 deg C across the board.
<Additional information>
This can be set with FIX-TEMP.
When FIX-TEMP is set to -6 deg C and TEMP-COM is set to -6 deg C, the control
temperature is offset by -12 deg C.
PRIAC-SW Improving the image quality in case of a drum charging fault
Note: This setting is cleared if APVC is executed with a new drum unit or if a
service mode (FUNCTION>D-GAMMA) is executed.
1
<Setting range>
0: No UP [Default], 1: 50 mA UP, 2: 100 mA UP
TEMPCON
2
Improving fixing (Increasing the fixing temperature)
Switching the multiple plain paper fixing temperature mode
<Note>
This is only valid for iR3530/3570/3570F/4530/4570/4570F.
1
<Setting range>
0: OFF (Default)
1: Prioritize productivity. Set the control temperature at -10 deg C across the board.
2: Set the control temperature at -6 deg C across the board.
3: Set the control temperature at -3 deg C across the board.
4: Prioritize fixing performance. Set the control temperature at +3 deg C across the
board.
5: Set the control temperature at +6 deg C across the board.
6: Set the control temperature at +10 deg C across the board.
7: Set the control temperature at +15 deg C across the board.
<Additional information>
This can be set with FIX-TEMP.
When FIX-TEMP is set to -6 deg C and TEMPCOM2 is set to -6 deg C, the control
temperature is offset by -12 deg C.
CONFIG
Selecting several types of firmware installed on the hard disk and switching the
country, language, and paper size type of this machine
1
<Adjustment method>
XXYYZZAAXX: Country (UP), YY: Language (ja), ZZ(00) Destination, AA(00):
Paper size type
The display contents conform to the display method of
(COPIER>DISPLAY>USER>LANGUAGE). Enclosed in the brackets are
defaults. The country and language are only displayed.
<Operating procedure>
1) Select <CONFIG>.
2) Select an item to reverse its display. Then press the + or - key to change the
contents.
3) Each time the + or - key is pressed, the contents change sequentially.
4) Display the intended contents at all items and press the OK key.
5) Turn the main power switch OFF and ON.
W/SCNR
Setting whether a scanner is present (Copy model)
1
<Setting range>
0: Printer model [Default]
1: Model with scanner
COPIER > OPTION > BODY
Sub-item
Description
Level
Summary of Contents for iR3570 Series
Page 1: ...Jan 17 2007 Service Manual iR4570 3570 2870 2270 Series...
Page 2: ......
Page 6: ......
Page 27: ...Chapter 1 Introduction...
Page 28: ......
Page 70: ......
Page 71: ...Chapter 2 Installation...
Page 72: ......
Page 146: ......
Page 147: ...Chapter 3 Basic Operation...
Page 148: ......
Page 150: ......
Page 154: ......
Page 155: ...Chapter 4 Main Controller...
Page 156: ......
Page 187: ...Chapter 5 Original Exposure System...
Page 188: ......
Page 217: ...Chapter 5 5 27 F 5 91...
Page 218: ......
Page 219: ...Chapter 6 Laser Exposure...
Page 220: ......
Page 222: ......
Page 230: ......
Page 231: ...Chapter 7 Image Formation...
Page 232: ......
Page 236: ......
Page 280: ......
Page 281: ...Chapter 8 Pickup Feeding System...
Page 282: ......
Page 388: ......
Page 389: ...Chapter 9 Fixing System...
Page 390: ......
Page 419: ...Chapter 9 9 27 F 9 148...
Page 420: ......
Page 421: ...Chapter 10 External and Controls...
Page 422: ......
Page 426: ......
Page 437: ...Chapter 10 10 11 F 10 12 2 Remove the check mark from SNMP Status Enabled...
Page 438: ...Chapter 10 10 12 F 10 13...
Page 440: ...Chapter 10 10 14 F 10 15...
Page 475: ...Chapter 11 MEAP...
Page 476: ......
Page 478: ......
Page 481: ...Chapter 12 Maintenance and Inspection...
Page 482: ......
Page 484: ......
Page 509: ...Chapter 13 Standards and Adjustments...
Page 510: ......
Page 512: ......
Page 521: ...Chapter 14 Correcting Faulty Images...
Page 522: ......
Page 528: ......
Page 537: ...Chapter 14 14 9 43mm s b Z x i j B iR4570_395 s u A B FM2 0287...
Page 538: ...Chapter 14 14 10...
Page 539: ...Chapter 14 14 11...
Page 585: ...Chapter 15 Self Diagnosis...
Page 586: ......
Page 588: ......
Page 623: ...Chapter 16 Service Mode...
Page 624: ......
Page 626: ......
Page 679: ...Chapter 17 Upgrading...
Page 680: ......
Page 682: ......
Page 693: ...Chapter 17 17 11 F 17 18 2 Click Start F 17 19 3 When the session has ended click OK...
Page 698: ...Chapter 17 17 16 F 17 28 2 Click Start F 17 29 3 When the session has ended click OK...
Page 710: ...Chapter 17 17 28 F 17 51 3 Click Start F 17 52 4 Click Save...
Page 712: ...Chapter 17 17 30 F 17 55 2 Select the data to download F 17 56 3 Click Start...
Page 714: ......
Page 715: ...Chapter 18 Service Tools...
Page 716: ......
Page 718: ......
Page 720: ......
Page 721: ...Jan 17 2007...
Page 722: ......