Errors
When the error occurs, the error LED will glow red. You can also confirm the current status from the LCD panel.
LCD Message
Description
Corrective Action
E10 UPS Running Off
Battery
The TeraStation is running on the UPS
battery due to a power outage.
Shut down the TeraStation safely and wait
until the power outage ends. If certain
settings are configured, the TeraStation
may shut down automatically when the
error is detected.
If the setting to use the UPS connected to
this TeraStation has been configured, the
UPS cable may be disconnected.
Verify that the UPS cable or LAN cable is
connected properly.
If the setting to use the UPS connected to
another TeraStation on the same network
has been configured, the LAN cable of this
TeraStation may be disconnected.
E11 Fan Failure
An error occurred in the fan speed.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or
dust are found, use a pair of tweezers, air
duster, or other tool to remove them. If the
error is displayed again, contact Buffalo
technical support for assistance.
E12 Cooling Failure
A rise in the system temperature may have
exceeded the allowable safety value.
Do not place objects in the area around
the TeraStation. Also, move the TeraStation
to a cool location.
E14 Can't Mount
Array x
The RAID array cannot be mounted.
Run the RAID array drive check in Settings.
E16 Drive x Not
Found
Unable to find the drive.
The drive may be disconnected or may
have failed. After shutting down, reinstall
the drive.
E22 Can't Mount
Drive x
Unable to mount the drive.
Format the drive. After formatting, if the
error still appears after rebooting, replace
the drive. If the error is displayed again,
contact Buffalo technical support for
assistance.
E27 Lost Failover
Target
Unable to find the backup TeraStation.
In the main TeraStation's Settings, navigate
to
Backup
-
Failover
to reconfigure the
backup TeraStation for failover.
200
Summary of Contents for TeraStation 5010 TS51210RH
Page 32: ...3 Click Create User 31...
Page 35: ...3 Click Add Group 34...
Page 103: ...2 Click to the right of Failover 3 Click the Periodic Sync tab 4 Click Edit 102...
Page 106: ...15Click Time Machine 105...
Page 107: ...16Click Select Backup Disk 17Select the TeraStation then click Use Disk 106...
Page 122: ...5 Click Edit 121...
Page 145: ...7 Click to the right of NFS 8 Click the Client Settings tab 144...
Page 168: ...3 Click Edit 167...
Page 169: ...4 Select or enter the desired MTU size and click OK 168...
Page 171: ...3 Click Edit 170...
Page 211: ...IEC60950 1 WARNING Hazardous moving parts Keep away from moving fan blades 210...