11
Select the RAID array which the failed drive was used from
Storage
-
RAID
in Settings and click
Delete RAID
Array
.
12
The "Confirm Operation" screen will open. Enter the confirmation number, then click
OK
.
13
In
Storage
-
Drives
, click
Format Drive
to format the new drive.
14
The "Confirm Operation" screen will open. Enter the confirmation number, then click
OK
.
15
In
Storage
-
RAID
, choose the RAID mode desired.
Create a shared folder before use.
Using a Hot Spare
If your TeraStation's drives are in a redundant RAID mode and you have a hot spare enabled, a malfunctioning drive
in the array is replaced by the spare drive and the RAID array is rebuilt automatically. The error LED will continue to
glow red for the failed drive even after the RAID array is rebuilt with the hot spare. After you replace the failed drive
with a new drive, follow the procedure below to configure a spare drive as a new drive.
1
The failed drive's error LED will be glowing red. Push its unlock button and swing the lock mechanism out.
2
Pull out the drive cartridge and remove it from the TeraStation.
3
Insert the new drive into the empty slot. Slide the drive in with the locking mechanism open.
4
Swing the lock back down until it clicks into place.
5
When the replaced drive is recognized, the error LED will flash.
6
Press the function button on the front of the TeraStation. The TeraStation will beep.
7
The replacement drive is automatically registered as a hot spare.
To use the replacement drive as a normal drive rather than a hot spare, navigate to
Storage
-
RAID
and click the RAID
array, select the new drive, and click
Set as a normal drive
.
Note:
If a drive fails in the RAID array before it is rebooted, the hot spare will not automatically replace the failed
drive. In this case, follow the procedure below to repair the array.
(1) In Settings, navigate to
Storage
-
Drives
.
(2) Click the drive that was configured as a hot spare, then click
Dismount Drive
.
(3) Click
Rediscover Drive
.
(4) Navigate to
Storage
-
RAID
.
(5) Choose the RAID array to repair.
(6) Click the drive that was previously configured as a hot spare, then click
Recover RAID Array
.
This will rebuild the RAID array.
180
Summary of Contents for TeraStation 5010 TS51210RH
Page 32: ...3 Click Create User 31...
Page 35: ...3 Click Add Group 34...
Page 103: ...2 Click to the right of Failover 3 Click the Periodic Sync tab 4 Click Edit 102...
Page 106: ...15Click Time Machine 105...
Page 107: ...16Click Select Backup Disk 17Select the TeraStation then click Use Disk 106...
Page 122: ...5 Click Edit 121...
Page 145: ...7 Click to the right of NFS 8 Click the Client Settings tab 144...
Page 168: ...3 Click Edit 167...
Page 169: ...4 Select or enter the desired MTU size and click OK 168...
Page 171: ...3 Click Edit 170...
Page 211: ...IEC60950 1 WARNING Hazardous moving parts Keep away from moving fan blades 210...