![Asus DS300f User Manual Download Page 410](http://html.mh-extra.com/html/asus/ds300f/ds300f_user-manual_26724410.webp)
391
Chapter 10: Troubleshooting
Enclosure
Overheat
Overheating is a potentially serious condition because the
excessively high temperatures can lead to disk drive failure and
controller malfunction.
Overheating usually results from:
•
Fan failure
•
Poor air circulation around the enclosure
Fan Failure
On ASUS Storage, there are two kinds of fans:
•
Power supply fan
•
RAID controller fan
If a power supply fan fails, you must replace the power supply.
If a RAID Controller fan fails, you can replace it onsite. See
page 313.
Air Circulation
Air circulation around the ASUS Storage subsystem might be a
more complex problem. Use the thermometer icons to help you
locate the specific hot spot. Check for these conditions:
• Accumulated dust or objects blocking the fans
•
Less than a minimum of 5 inches (13 cm) space between the
back of the ASUS Storage and the wall or other object
•
Ambient temperature above 95°F (35°C) where the ASUS
Storage is operating
Cooling Down the Enclosure
To cool down a ASUS Storage enclosure:
• Correct any problems identified above
•
Power down the ASUS Storage and let it sit for an hour or
longer
Summary of Contents for DS300f
Page 1: ...ASUS Storage DS300f DS300i User Manual Version 1 0 ...
Page 10: ...x Language 178 Closing Smart NAS Console 178 ...
Page 27: ...8 Chapter 1 Introduction to ASUS Storage ...
Page 57: ...3 8 Chapter 2 ASUS Storage Installation ...
Page 73: ...54 Chapter 3 ASUS Storage Setup ...
Page 164: ...14 5 Chapter 4 Management with ASUS Storage Management ...
Page 221: ...202 Chapter 5 SmartNAVI ...
Page 235: ...216 Chapter 6 Management with the CLU Figure 4 Controller Status LED Controller Status ...
Page 337: ...318 Chapter 8 Maintenance ...
Page 425: ...406 Chapter 11 Support ...
Page 433: ...414 Appendix A Setting up NAS Network Drives ...
Page 449: ...430 Index ...