Programming Manual for Digital Key Telephone System
GDK-162/100/34e
Admin Programming
99A Software 1/6/00
A-93
BTN
ITEM
DEFAULT
RANGE
REMARK
18
ACD Print Timer
000
000 - 255
(3 Digits)
Determines the amount of time between repeated ACD
database prints. Zero means no print out.
19
Ring Phase
Timer
5
2 - 5
(1 Digit)
Determines the ring phase of SLT.
(5 SEC : 1SEC ON / 4SEC OFF)
20
Camp-on Recall
Timer
050
000 - 200
(3 Digits)
If a station transfers to busy station and hang up, this recall
timer is assigned.
21
Station Auto
Release Timer
060
000 - 200
(3 Digits)
If a station hears ring back tone and no action is taken, this
timer is assigned. When this timer is expired the station is
released.
22
DCOB Type
2
0 - 2
0 : Sweden/Cyprus 1: Italy 2: Korea/Australia
23
Ready Signal
timer
007
000 - 255 For DCOB Signal Timer (used at DCOB)
24
Erase Wake-Up
Fail Ring Timer
20
0-99
After a Wake-up fail ring invokes on the System Attendant,
the alarm ring exists during this timer. Then if this timer
expires, the alarm ring will be disappeared.
TABLE 5.5.1 Button Configuration for System Timers - II (PGM 44)
5.6 ADMIN PASSWORD (PGM 45)
Admin Password can be assigned to enter Admin Programming mode for only Administrator who
knows the Admin Password.
It is not assigned by default.
PROCEDURE
ADMIN PASSWORD
....
(1)
[TRANS/PGM]
+ 45.
ADMIN PASSWORD
1234
(2) To assign Admin Password, enter 4 digits number, then
entered admin password will be displayed on LCD. Otherwise
to delete the admin password, press the
[SPEED]
button. (Ex
1234)
ENTER PROGRAM CODE
(3) Press the
[HOLD/SAVE]
button for updating database
permanently.
ENTER PROGRAM CODE
Press [
] button instead of the
[HOLD/SAVE]
button, then
system goes to
PGM number enter
mode
without updating
system memory.