Programming Manual for Digital Key Telephone System
GDK-162/100/34e
Admin Programming
99A Software 1/6/00
A-126
5.34 RING FREQUENCY (PGM 75)
Frequency for 4 differential rings may be changed to the closest ring frequency that provides. It is
provided for only digital keyset and it is assigned at PGM 38-BTN 1.
PROCEDURE
RING FREQUENCY
RNG1 RNG2 RNG3 RNG4
(1)
[TRANS/PGM]
+ 75.
RING FREQUENCY
T1:1000 T2:1020 (0:NONE)
(2) To change ring frequency of called party, press BTN 1-4 and
dial 1 (T1) or 2 (T2) and dial 4 digits of new frequency (Ex.
Press BTN 1 to change for new ring 1 frequency).
ENTER PROGRAM CODE
(6)(3)
Press the
[HOLD/SAVE]
button for updating database
permanently.
ENTER PROGRAM CODE
Press [
] button instead of the
[HOLD/SAVE]
button, then
system goes to
PGM number enter
mode
without updating
system memory.
BTN
ITEM
RANGE
DEFAULT
REMARK
1
Ring 1 Frequency
0000 - 9999
T1: 1000 T2: 1020
2
Ring 2 Frequency
0000 - 9999
T1: 0890 T2: 0910
3
Ring 3 Frequency
0000 - 9999
T1: 1260 T2: 1280
4
Ring 4 Frequency
0000 - 9999
T1: 0800 T2: 0820
TABLE 5.34.1 Button Configuration for Ring Frequency (PGM 75)
Formatted: Bullets and Numbering