Programming Manual for Digital Key Telephone System
GDK-162/100/34e
Admin Programming
99A Software 1/6/00
A-74
4.2 CO LINE ATTRIBUTE
– II (PGM 31)
PROCEDURE
CO LINE ATT 2
ENTER CO RANGE
(1)
[TRANS/PGM]
+ 31.
01-05 CO DTMF UNA GRND
MTR:NO VOC DROP N-DVU
(2) Enter CO line range (Ex. 01-05). Initially LEDs of BTN 1-4, 6, 8
and LCD indicate current programming status of the first CO
line in range.
(3) To program, use the BTN as Table 4.2.2. BTN 1-4, 6-8 toggle
on and off. Press BTN 5 and enter related data for setting
metering signal, then it will be displayed entered data on LCD.
Note
. Private lines should not be programmed for UNA operations.
CO LINE ATT 2
ENTER CO RANGE
(4) Press the
[HOLD/SAVE]
button for updating database
permanently.
CO LINE ATT 2
ENTER CO RANGE
Press [
] button instead of the
[HOLD/SAVE]
button, then
system goes to step (1) with no updating system memory.
BTN
ITEM
RANGE
DEFAULT
(LED)
REMARK
1
CO Type
CO/PBX
CO (ON)
When marked PBX, a 1 or 2 digit dial code may be
entered after which toll restriction is applied.
2
CO Dial Type
DTMF/Pulse
DTMF (ON) Each CO line can be programmed to be either DTMF
(tone) or dial pulse.
3
UNA
YES/NO
NO (OFF)
The allowance of Universal Night Answer service
4
CO Flash
Type
Ground/
Loop
Loop (OFF) Flash types of CO line are Loop Flash (timed-break) and
Ground Flash
5
Metering Type
0
– 6
0 (OFF)
There are 7 metering signal types;
0 : None
1 : 50Hz
2 : 12KHz
3 : 16KHz
4 : Singular Polarity Reverse (SPR)
5 : Plural Polarity Reverse (PPR)
6 : No Polarity Reverse (NPR)
6
Voice/Data
Voice/Data
Voice (ON)
Determines that the CO line use for voice or data. (Only
for cept)